17 | Technical data
Installer reference guide
234
EVLQ05+08CA + EHYHBH05A + EHYHBH/X08A + EHYKOMB33AA
Daikin Altherma hybrid heat pump
4P355634-1G – 2022.09
17 Technical data
A subset of the latest technical data is available on the regional Daikin website
(publicly accessible). The full set of latest technical data is available on the Daikin
Business Portal (authentication required).
In this chapter
17.1 Piping diagram: Outdoor unit................................................................................................................................................. 234
17.2 Piping diagram: Indoor unit.................................................................................................................................................... 235
17.3 Wiring diagram: Outdoor unit................................................................................................................................................ 236
17.4 Wiring diagram: Indoor unit................................................................................................................................................... 237
17.5 Wiring diagram: Gas boiler..................................................................................................................................................... 243
17.6 ESP curve: Indoor unit ............................................................................................................................................................ 244
17.7 Technical specifications: Gas boiler ....................................................................................................................................... 245
17.7.1 General ................................................................................................................................................................... 245
17.7.2 Energy-related products specifications ................................................................................................................. 247
17.7.3 Appliance category and supply pressure............................................................................................................... 248
17.1 Piping diagram: Outdoor unit
(6.4 CuT)
(15.9 CuT)
7.9CuT
7.9CuT
7.9CuT
7.9CuT
7.9CuT
7.9CuT
7.9CuT
7.9CuT
12.7CuT
12.7CuT
7.9CuT
6.4CuT
12.7CuT
12.7CuT
12.7CuT
12.7CuT
6.4CuT
7.9CuT
7.9CuT
4.0CuT
4.0CuT
4.0CuT
4.0CuT
7.9CuT
7.9CuT
7.9CuT
6.4CuT 6.4CuT
M
P
P >
6.4CuT
3TW60815-1
OUTDOOR UNIT
OUTDOOR AIR TEMPERATURE
THERMISTOR
HEAT EXCHANGER
HEAT
EXCHANGER
THERMISTOR
CAPILLARY TUBE 1
CAPILLARY TUBE 2
CAPILLARY TUBE 3
CAPILLARY TUBE 4
REFRIGERANT FLOW
COOLING
HEATING
FIELD PIPING
FIELD PIPING
LIQUID
STOP VALVE
GAS STOP VALVE
WITH SERVICE PORT
FILTER
FILTER
MOTOR OPERATED
VALVE
MUFFLER
WITH
FILTER
PROPELLER FAN
PRESSURE
SENSOR
MUFFLER
WITH
FILTER
HIGH
PRESSURE
SWITCH
MUFFLER
MUFFLER
DISCHARGE PIPE
THERMISTOR
COMPRESSOR
ACCUMULATOR