EasyManua.ls Logo

Daikin Altherma EHYHBH05A Series - To Close the Outdoor Unit; To Close the Indoor Unit; To Close the Gas Boiler

Daikin Altherma EHYHBH05A Series
264 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
7 | Unit installation
Installer reference guide
55
EVLQ05+08CA + EHYHBH05A + EHYHBH/X08A + EHYKOMB33AA
Daikin Altherma hybrid heat pump
4P355634-1G – 2022.09
7.2.6 To close the outdoor unit
1 Close the switch box cover.
2 Close the service cover.
NOTICE
When closing the outdoor unit cover, make sure that the tightening torque does NOT
exceed 4.1N•m.
7.2.7 To close the indoor unit
1 Close the switch box.
2 Mount the side plate to the unit.
3 Mount the top plate.
NOTICE
When closing the indoor unit cover, make sure that the tightening torque does NOT
exceed 4.1N•m.
Before doing the configuration of the heat pump module, make sure that the
hybrid module and gas boiler are installed correctly.
7.2.8 To close the gas boiler
1 Hook the top of the front panel into the top of the gas boiler.

Table of Contents