10 | Configuration
Installer reference guide
142
EVLQ05+08CA + EHYHBH05A + EHYHBH/X08A + EHYKOMB33AA
Daikin Altherma hybrid heat pump
4P355634-1G – 2022.09
# Code Description
[A.2.2.5] [C-06] Contact type add.
In external room thermostat control with 2
leaving water temperature zones, the type of the
optional room thermostat for the additional
leaving water temperature zone must be set.
1 (Thermo ON/OFF): See Contact type
main. Connected on the indoor unit (X2M/1a).
2 (H/C request)(default): See Contact
type main. Connected on the indoor unit
(X2M/1a and 2a).
[A.2.2.B] [C-08] External sensor
When an optional external ambient sensor is
connected, the type of the sensor must be set.
0 (No)(default): NOT installed. The thermistor
in the user interface and in the outdoor unit
are used for measurement.
1 (Outdoor sensor): Installed. The outdoor
sensor will be used to measure the outdoor
ambient temperature. Remark: For some
functionality, the temperature sensor in the
outdoor unit is still used.
2 (Room sensor): Installed. The temperature
sensor in the user interface is NOT used
anymore. Remark: This value has only meaning
in room thermostat control.
Digital I/O PCB
Modification of these settings is only needed when the optional digital I/O PCB is
installed. The digital I/O PCB has multiple functionality which need to be
configured.
# Code Description
[A.2.2.6.2] [D-07] Solar kit
Indicates if the domestic hot water tank is also
heated by thermal solar panels.
0 (No)(default): NOT installed.
1 (Yes): Installed. The domestic hot water tank
can –besides by the boiler– also be heated by
thermal solar panels. Set this value if thermal
solar panels are installed.