ESIE09-08B Field Setting
Test Operation 103
[C] Leaving water temperature limits
To prevent misuse concerning leaving water temperatures, it is possible to limit the set points.
[C-00] Set point: leaving water maximum t
emperature
[C-01] Set point: leaving water minimum te
mperature
First
code
Second
code Setting name
Default
value Range Step Unit
C Leaving water temperature limits
00 Set point: leaving water maximum
temperature
80 37~80 1 °C
01 Set point: le
aving water minimum
temperature
25 25~37 1 °C