ESIE09-08B Field Setting
Test Operation 113
The numbers in the "No." column represent the number of times to press the
SET (BS2) button.
Note : 8HP not important to change settings.
No. Setting item
LED display
Data display
H1P H2P H3P H4P H5P H6P H7P
14
Contents of malfunction (the
latest)
Malfunction
code table
Refer to page
128.
15
Contents of malfunction
(1 cycle before)
16
Contents of malfunction
(2 cycle before)
20 Contents of retry (the latest)
21 Contents of retry (1 cycle before)
22 Contents of retry (2 cycle before)
25
Normal judgment of outdoor units
PC board
c
Lower 2 digits:

Abnormal

Normal

Unjudgment
c. Monitor mode
<Selection of setting item>
<Confirmation on setting contents>
To enter the monitor mode, push the
MODE (BS1) button when in “Setting
mode 1”.
Push the SET (BS2) button and set
the LED display to a setting item.
Push the RETURN (BS3) button to
display different data of set items.
Push the RETURN (BS3) button and
switches to the initial status of
“Monitor mode”.
Push the MODE (BS1) button and
returns to “Setting mode 1”.
(V2765)