31
ACCESSORIES
DZ13SA
Model Description
DZ13SA
018
DZ13SA
024
DZ13SA
030
DZ13SA
036
DZ13SA
042
DZ13SA
048
DZ13SA
060
AFE18-60A All-Fuel Kit X X X X X X X
ASC 01 Anti-Short Cycle Kit X X X X X X X
CSR-U-1
4
Hard-start Kit X X X X
CSR-U-2
4
Hard-start Kit X X
CSR-U-3
4
Hard-start Kit X X
FSK01A
2
Freeze Protection Kit X X X X X X X
LSK02*
Liquid Line Solenoid Kit X X X X X X X
OT/EHR18-60 Emergency Heat Relay kit X X X X X X X
OT18-60A
3
Outdoor Thermostat w/Lockout Stat X X X X X X X
TX2N4A
4
TXV Ki t X X
TX3 N 4
4
TXV Ki t X X
TX5 N 4
4
TXV Ki t X X X
DZ13SN
Model Description
DZ13SN
018
DZ13SN
024
DZ13SN
030
DZ13SN
036
DZ13SN
042
DZ13SN
048
DZ13SN
060
AFE18-60A All-Fuel Kit X X X X X X X
ASC 01 Anti-Short Cycle Kit X X X X X X X
CSB-15 Sound Blanket X X X
CSB-16 Sound Blanket X X X X
CSR-U-1
4
Hard-start Kit X X X X
CSR-U-2
4
Hard-start Kit X X
CSR-U-3
4
Hard-start Kit X X
FSK01A
2
Freeze Protection Kit X X X X X X X
LSK02*
Liquid Line Solenoid Kit X X X X X X X
OT/EHR18-60 Emergency Heat Relay kit X X X X X X X
OT18-60A
3
Outdoor Thermostat w/Lockout Stat X X X X X X X
TX2N4A
5
TXV Ki t X X
TX3 N 4
5
TXV Ki t X X
TX5 N 4
5
TXV Ki t X X X
DZ13SA THREE-PHASE
Model Description
DZ13SA
036*
DZ13SA
048*
DZ13SA
048*
DZ13SA
060*
DZ13SA
060*
AFE18-60A
All-Fuel Kit X X X X X
ASC 01 Anti-Short Cycle Kit X X X X X
FSK01A
2
Freeze Protection Kit X X X X X
LSK02* Liquid Line Solenoid Kit X X X X X
OT/EHR18-60 Emergency Heat Relay kit X X X X X
OT18-60A
3
Outdoor Thermostat w/Lockout Stat X X X X X
TX3 N 4
5
TXV Ki t X X
TX5 N 4
5
TXV Ki t X X X
CSB-15 Sound Blanket Kit X X X X
CSB-16 Sound Blanket Kit X
LAKT01 Low Ambient Kit X X X X X
1
Contains 20 brackets; four brackets needed to anchor unit to pad
2
Installed on indoor coil
3
Required f or heat pump applications w here ambient temperatures fall below 0°F w ith 50% or higher relative humidity.
4
Condensing units and heatp pumps w ith reciprocating compressors require the use of start-assist components w hen used in
conjunction w ith an indoor coil using a non-bleed expansion valve ref rigerant metering device.
5
Field-installed, non-bleed, expansion valve kit — Condensing units and heat pumps w ith reciprocating compressors require the use
of start-assist components w hen used in conjunction w ith an indoor coil using a non-bleed thermal expansion valve refrigerant.