6 | Application guidelines
Installer reference guide
40
ERLA03DAV3 + EHFZ03S18DJ3V
Daikin Altherma 3 R F
4P596821-1B – 2021.10
6.4.4 DHW pump for instant hot water
Setup
a Cold water IN
b Hot water OUT (shower (field supply))
c DHW pump (field supply)
d Recirculation connection
▪ By connecting a DHW pump, instant hot water can be available at the tap.
▪ The DHW pump and the installation are field supply and the responsibility of the
installer. For the electrical wiring, see "9.3.6To connect the domestic hot water
pump"[4101].
▪ For more information about connecting the recirculation connection, see
"8.6.4To connect the recirculation piping"[484].
Configuration
▪ For more information, see "10Configuration"[4110].
▪ You can program a schedule to control the DHW pump via the user interface. For
more information, see the user reference guide.
6.4.5 DHW pump for disinfection
Setup
a Cold water IN
b Hot water OUT (shower (field supply))
c DHW pump (field supply)
d Heater element (field supply)
e Non‑return valve (field supply)
▪ The DHW pump is field-supplied and its installation is the responsibility of the
installer. For the electrical wiring, see "9.3.6To connect the domestic hot water
pump"[4101].