5/10
Breadcrumb Field code Setting name Range, step
Default value
Date Value
Field settings table
Installer setting at variance with
default value
└─ Booster heater
9.4.1 [6-02] R/W 0~10kW, step: 0,2kW
0kW
9.4.3 [8-03] R/W 20~95 min, step: 5 min
50 min
9.4.4 [4-03] R/W 0: Restricted
1: Allowed
2: Overlap
3: Compressor off
4: Le
g
ionella onl
y
Installer settings
└─ Emergency
9.5.1 [4-06] R/W 0: Manual
1: Automatic(normal SH/DHW ON)
2: Auto red SH/DHW ON
3: Auto red SH/DHW OFF
4: SH ON/DHW OFF
9.5.2 [7-06] R/W
0: Disabled
1: Enabled
Installer settings
9.7 [4-04]
0: Intermittent (not to be used)
1: Continuous
2: Of
f
└─ Benefit kWh power supply
9.8.2 [D-00] R/W
0: None
1: BSH only
2: BUH only
3: All heaters
9.8.3 [D-05] R/W 0: Forced off
1: As normal
9.8.4 [D-01] R/W
0: No
1: Active open
2: Active closed
3: Smart
g
rid
9.8.6 0: No
1: Yes
9.8.7 Enable Room buffering
0: No
1: Yes
9.8.8 0~20 kW, step: 0,5 kW
20 kW
└─ Power consumption control
9.9.1 [4-08] R/W
0: No limitation
1: Continuous
2: Di
g
ital in
p
uts
9.9.2 [4-09] R/W 0: Current
1: Power
9.9.3 [5-05] R/W 0~50 A, step: 1 A
50
A
9.9.4 [5-05] R/W 0~50 A, step: 1 A
50
A
9.9.5 [5-06] R/W 0~50 A, step: 1 A
50
A
9.9.6 [5-07] R/W 0~50 A, step: 1 A
50
A
9.9.7 [5-08] R/W 0~50 A, step: 1 A
50
A
9.9.8 [5-09] R/W 0~20 kW, step: 0,5 kW
20 kW
9.9.9 [5-09] R/W 0~20 kW, step: 0,5 kW
20 kW
9.9.A [5-0A] R/W 0~20 kW, step: 0,5 kW
20 kW
9.9.B [5-0B] R/W 0~20 kW, step: 0,5 kW
20 kW
9.9.C [5-0C] R/W 0~20 kW, step: 0,5 kW
20 kW
9.9.D [4-01]
0: None
1: BSH
2: BUH
└─ Energy metering
9.A.1 [D-08] R/W
0: No
1: 0,1 pulse/kWh
2: 1 pulse/kWh
3: 10 pulse/kWh
4: 100 pulse/kWh
5: 1000
p
ulse/kWh
9.A.2 [D-09] R/W
0: No
1: 0,1 pulse/kWh
2: 1 pulse/kWh
3: 10 pulse/kWh
4: 100 pulse/kWh
5: 1000 pulse/kWh
6: 100 pulse/kWh (PV meter)
7: 1000
p
ulse/kWh
(
PV meter
)
└─ Sensors
9.B.1 [C-08] R/W
0: No
1: Outdoor sensor
2: Room sensor
9.B.2 [2-0B] R/W -5~5°C, step: 0,5°C
0°C
9.B.3 [1-0A] R/W
0: No averaging
1: 12 hours
2: 24 hours
3: 48 hours
4: 72 hours
└─ Bivalent
9.C.1 [C-02] R/W
0: No
1: Bivalent
9.C.2 [7-05] R/W
0: Very high
1: High
2: Medium
3: Low
4: Ver
y
low
Ext. amb. sensor offset
Averaging time
Bivalent
Boiler efficiency
Limit 3
Limit 4
Priority heater
Electricity meter 1
Electricity meter 2 / PV meter
External sensor
Limit 2
Limit 3
Limit 4
Limit
Limit 1
Limit 2
Allow heater
Power consumption control
Type
Limit
Limit 1
Allow pump
Benefit kWh power supply
Allow electric heaters
Limit setting kW
Capacity
BSH eco timer
Operation
Water pipe freeze prevention
Emergency
HP Forced OFF
(*1) EWAA*
(*2) EWYA*
(#) Setting is not applicable for this unit. 4P627274-1 - 2020.09