EasyManua.ls Logo

Daikin FTKS50BVMA8 - Fan Rotor; Fan Motor

Daikin FTKS50BVMA8
19 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Fan Rotor / Fan Motor Si041253_A
14 Removal Procedure
10.Fan Rotor / Fan Motor
Warning
Be sure to wait for 10 minutes or more after turning off all power supplies before
disassembling work.
Step Procedure Points
1
Remove the 2 screws.
You can remove the fan
rotor without detaching the
right side plate.
2
Lift the right side plate
and remove it.
3
Remove the screw and
remove the fan motor
fixing plate.
When reassembling the fan
motor and the fan rotor,
provide as much as 5 mm of
play between the side face
of the rotor and the bottom
frame.
(1) Insert the fan motor with
approx. 5 mm left.
(2) Tighten the screw until it
stops. Then give the screw
one more turn.
(3) Rotate the fan rotor and
confirm the fan motor and
the fan rotor are installed
appropriately.
(4) Tighten the screw
completely if appropriate.
(5) If not appropriate, go back to
(1).
4
Loosen the screw of the
fan rotor.
5
Remove the fan motor.
Right
side
plate
(R16544)
Fan motor fixing plate
(R17920)
5 mm
Side face of rotor
(R2808)
Side face of
bottom frame
(R9582)
(R17743)
Fan rotor
Fan motor
(R13230)

Related product manuals