EasyManua.ls Logo

Daikin MCK70ZVM-W - Humidifying and Air Purifying Operation

Daikin MCK70ZVM-W
58 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
23
Operation
Operation
Humidifying and Air Purifying Operation
Fill the water tank with water.
Page 16, 17
1. Press .
2. Press to switch the humidity setting.
Each press cycles between the humidity setting lamps (white).
(High) OFF(Low) (Standard)
Pressing during operation will cause operation to stop.
After operation stops, humidifying lter drying operation will start automatically.
Low
Operation is carried out automatically with a humidity of 40% (*) as a rough estimate.
Standard
Operation is carried out automatically with a humidity of 50% (*) as a rough estimate.
High
Operation is carried out automatically with a humidity of 60-70% (*) as a rough estimate.
When the target humidity is reached, the humidifying lter unit will stop.
* Depending on the indoor and outdoor temperature and humidity, and the room conditions, the target humidity may be
exceeded (or not reached).
Page 52, 53
Attention
Make sure that the humidifying lter unit is attached when performing this operation.
Change the water in the humidifying tray and water tank every day.
Be sure to use tap water for the water in the water tank.
As leaving any residual water in the humidifying tray will lead to bad odours and dirt build-up, be sure to discard any
residual water in the humidifying tray once a day to perform Humidifying Operation.
Perform during Humidifying Operation as well as Air Purifying Operation.
(Humidication only operation cannot be performed.)
Even if you have selected an airow rate that suits your preferences, if the water supply lamp lights up, the airow rate will
change to “Quiet”.
If you do not want the airow rate to change to “Quiet”, change the setting.
Page 33, 34
(Depending on the degree of odour and dust, the airow rate may not change to “Quiet”.)
In order to make it easier for the humidifying lter to absorb water, the “Turbo” airow rate will be suppressed for about
10minutes from the start of the humidifying operation. After that, the operating sound changes because the airow rate also
changes to the set airow rate.
Note
No steam (vapor) or fog can be seen.
The room temperature may drop during Humidifying Operation.
Splashing sounds may be heard during Humidifying Operation, but this is not a malfunction.
Page 48
If the set humidity is reached or the water supply lamp lights up during Humidifying Operation, Humidifying Operation will stop,
but Air Purifying Operation will continue.
01_EN_3P693798-1B.indd 23 2023/06/26 13:34:03