Advanced Settings
Function 1 2 3 4
Monitoring mode within
AUTO Operation and ECONO
MODE (ON/OFF)
Setting at the time of purchase: ON
The sensitivity of the sensors decrease while
the fan is stopped during Monitoring mode.
If you do not want the sensitivity of the
sensors to be decreased, set to “OFF”.
• When set to “OFF”, Monitoring mode will not be
performed.
Setting can be performed either
during operation or while operation is
stopped.
Press for about
5seconds, and when a
short beep sounds, press
while continuing
to hold down
.
When a short beep
sounds, release
and
.
The humidity setting lamps
(Low) blinks, then lights up.
[Blinking → Lit up]
According to the current setting,
the ECONO MODE lamp will be
displayed as follows.
[Blinking → Lit up]
“ON”
[Unlit]
“OFF”
Press to change the setting*.
Each press cycles between “ON” and
“OFF”.
[Lit up]
“ON”
[Unlit]
“OFF”
Press .
A short beep sounds, the Humidity
setting lamps (Low) blinks, and the
ECONO MODE lamp changes to the
following display according to the
setting.
[Blinking]
[Blinking]
“ON”
[Unlit]
“OFF”
While the lamp is blinking,
unplug the power supply
plug, wait at least
5seconds, and then insert
the power supply plug
again.
Setting is now complete.
Power supply plug
Power socket
• If this procedure is not performed,
the unit will not return to regular
operation mode.
• The settings will be remembered
even if the power supply plug is
removed.
Airow rate range for AUTO
FAN (4 levels/3 levels)
Setting at the time of purchase: 4 levels
If you are concerned about the operation noise
during AUTO FAN MODE/MOIST MODE/AUTO
Operation, switch from “4 levels” to “3 levels”.
Airow rate range
4 levels: “Quiet” “Low” “Standard” “High”
3 levels: “Quiet” “Low” “Standard”
Setting can be performed either
during operation or while operation is
stopped.
Press for about
5seconds, and when a
short beep sounds, press
while continuing
to hold down
.
When a short beep
sounds, release
and
.
The AUTO FAN MODE lamp
blinks, then lights up.
[Blinking → Lit up]
According to the current setting, the
FAN lamp will be displayed as
follows.
[Unlit]
“4 levels”
[Blinking → Lit up]
“3 levels”
Press to change the setting*.
The airow rate switches between
“4levels” and “3 levels” with each press.
[Unlit]
“4 levels”
[Lit up]
“3 levels”
Press .
A short beep sounds, the AUTO FAN
MODE lamp blinks, and the FAN lamp
changes to the following display
according to the setting.
[Blinking]
[Unlit]
“4 levels”
[Blinking]
“3 levels”
* If the lamps do not change even after the settings were changed, unplug the unit, wait at least 5 seconds, then re-insert the power supply plug and
repeat the above procedure from the beginning.