SiBE121135_A Function of RA Indoor Unit
Function and Control 98
To use WEEKLY TIMER operation
Setting mode
• Make sure the day of the week and time are set. If not, set the day of the week and time.
6:00 8:30 17:30 22:00
25˚C
27˚C
[Monday]
Setting Displays
Day and number
ON/OFF
Time
Temperature
1.
Press .
• Pressing changes the reservation number and the day of the week.
3.
Press .
4.
Press to select the desired mode.
ON TIMER
OFF TIMER
blank
5.
Press .
Program 1
ON
Program 2
OFF
Program 3
ON
Program 4
OFF
• The day of the week and the reservation number of the current day will be displayed.
• 1 to 4 settings can be made per day.
2.
Press to select the desired day of the week
and reservation number.
• The day of the week and reservation number will be set.
• “ ” and “ ” blink.
• Pressing changes “ ” or “ ” setting in sequence.
Pressing alternates the following items appearing on the LCD in rotational
sequence.
• In case the reservation has already been set, selecting “blank” deletes the
reservation.
• Go to step
9
if “blank” is selected.
• To return to the day of the week and reservation number setting, press .
• The ON/OFF TIMER mode will be set.
• “ ” and the time blink.