EasyManua.ls Logo

Daikin Super multi NX E Series

Daikin Super multi NX E Series
302 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SiBE121135_A Indoor Unit
Printed Circuit Board Connector Wiring Diagram 58
Sensor PCB
Service PCB
Display PCB
LED3 does not function.
1) S49 Connector for control PCB
2) RTH2 (R1T) Room temperature thermistor
S49
RTH2
3P191450-1
1) S27 Connector for control PCB
2) SW2-4 Switch for upward airflow limit setting
Refer to page 257 for detail.
Keep the other switches as factory setting.
3) SW4 (S4W) Switch for airflow selection
Refer to page 79 for detail.
S27
SW4
SW2-4
3P191448-1
1) S47 Connector for control PCB
2) SW1 (S1W) Forced cooling operation [ON/OFF] button
3) LED1 (H1P) LED for operation (green)
4) LED2 (H2P) LED for timer (yellow)
S47SW1LED2
LED1
3P191447-1

Table of Contents

Related product manuals