ED34-862 Specifications
FXCQ-M 125
3
Ceiling Mounted Cassette Type (Double-Flow)
Note:
∗1 Indoor temp. : 27°CDB, 19.5°CWB / outdoor temp. : 35°CDB / Equivalent piping length : 7.5 m, level difference : 0 m.
∗2 Indoor temp. : 27°CDB, 19.0°CWB / outdoor temp. : 35°CDB / Equivalent piping length : 7.5 m, level difference : 0 m.
3 Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat.
∗4 Anechoic chamber conversion value, measured at a point 1.5 m downward from the unit center. During actual operation, these values are
normally somewhat higher as a result of ambient conditions.
5 Refer to page 133 for Fan Motor Input.
Model FXCQ50MVE FXCQ63MVE FXCQ80MVE FXCQ125MVE
∗1 Cooling Capacity (19.5°CWB)
kcal/h 5,000 6,300 8,000 12,500
Btu/h 19,800 24,900 31,700 49,500
kW 5.8 7.3 9.3 14.5
∗2 Cooling Capacity (19.0°CWB) kW 5.6 7.1 9.0 14.0
Casing Galvanized Steel Plate Galvanized Steel Plate Galvanized Steel Plate Galvanized Steel Plate
Dimensions: (H×W×D) mm 305×990×600 305×1,175×600 305×1,665×600 305×1,665×600
Coil (Cross
Fin Coil)
Rows×Stages×Fin Pitch mm 2×10×1.5 2×10×1.5 2×10×1.5 2×10×1.5
Face Area m² 2×0.145 2×0.184 2×0.287 2×0.287
Fan
Model 2D17K1AA1 2D17K2AA1VE 3D17K2AA1 3D17K2AB1
Type Sirocco Fan Sirocco Fan Sirocco Fan Sirocco Fan
Motor Output × Number
of Units
W 20×1 30×1 50×1 85×1
Air Flow Rate (H/L)
m³/min 12/9 16.5/13 26/21 33/25
cfm 424/318 582/459 918/741 1,165/883
Drive Direct Drive Direct Drive Direct Drive Direct Drive
Temperature Control
Microprocessor Thermostat
for Cooling and Heating
Microprocessor Thermostat
for Cooling and Heating
Microprocessor Thermostat
for Cooling and Heating
Microprocessor Thermostat
for Cooling and Heating
Sound Absorbing Thermal Insulation Material Glass Wool/Urethane Foam Glass Wool/Urethane Foam Glass Wool/Urethane Foam Glass Wool/Urethane Foam
Piping
Connections
Liquid Pipes mm
φ6.4 (Flare Connection) φ9.5 (Flare Connection) φ9.5 (Flare Connection) φ9.5 (Flare Connection)
Gas Pipes mm φ12.7 (Flare Connection) φ15.9 (Flare Connection) φ15.9 (Flare Connection) φ15.9 (Flare Connection)
Drain Pipe mm
VP25
External Dia. 32
Internal Dia. 25
VP25
External Dia. 32
Internal Dia. 25
VP25
External Dia. 32
Internal Dia. 25
VP25
External Dia. 32
Internal Dia. 25
Machine Weight (Mass) kg 32 35 47 48
∗4 Sound Level (H/L) (220V) dBA 34/29 37/32 39/34 44/38
Safety Devices
Fuse. Thermal Protector for
Fan Motor.
Fuse. Thermal Protector for
Fan Motor.
Fuse. Thermal Protector for
Fan Motor.
Fuse. Thermal Protector for
Fan Motor.
Refrigerant Control Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve
Connectable Outdoor Unit R-410A PA Series R-410A PA Series R-410A PA Series R-410A PA Series
Decoration
Panels
(Option)
Model BYBC50G-W1 BYBC63G-W1 BYBC125G-W1 BYBC125G-W1
Panel Color White (10Y9/0.5) White (10Y9/0.5) White (10Y9/0.5) White (10Y9/0.5)
Dimensions: (H×W×D) mm 53×1,245×680 53×1,430×680 53×1,920×680 53×1,920×680
Air Filter
Resin Net
(with Mold Resistant)
Resin Net
(with Mold Resistant)
Resin Net
(with Mold Resistant)
Resin Net
(with Mold Resistant)
Weight kg 8.5 9.5 12 12
Standard Accessories
Operation Manual.
Installation Manual. Paper
Pattern for Installation.
Washer for Hanging
Brackets. Clamp Metal.
Drain Hose. Insulation for
Fitting. Washer Fixing
Plates. Sealing Pads.
Clamps. Screws. Washers.
Operation Manual.
Installation Manual. Paper
Pattern for Installation.
Washer for Hanging
Brackets. Clamp Metal.
Drain Hose. Insulation for
Fitting. Washer Fixing
Plates. Sealing Pads.
Clamps. Screws. Washers.
Operation Manual.
Installation Manual. Paper
Pattern for Installation.
Washer for Hanging
Brackets. Clamp Metal.
Drain Hose. Insulation for
Fitting. Washer Fixing
Plates. Sealing Pads.
Clamps. Screws. Washers.
Operation Manual.
Installation Manual. Paper
Pattern for Installation.
Washer for Hanging
Brackets. Clamp Metal.
Drain Hose. Insulation for
Fitting. Washer Fixing
Plates. Sealing Pads.
Clamps. Screws. Washers.
Drawing No. C : 3D039413
( )( )( )( )
Conversion Formulae
kcal/h=kW×860
Btu/h=kW×3412
cfm=m³/min×35.3
Все каталоги и инструкции здесь: http://splitoff.ru/tehn-doc.html