Piranha Color Camera User’s Manual 87
DALSA 03-032-10211-01 5/9/2007
Message Description
Error 04: Incorrect
parameter value>
This error is returned for:
- Alpha character received instead of numeric character or visa versa.
- Float where integer expected.
- Not an element of the set of possible values. E.g., Baud Rate.
- Outside the range limit
Error 05: Command
unavailable in this
mode>
E.g. Set sync frequency (ssf) when in external sync mode 3 (sem).
Error 06: Timeout> Command not completed in time. E.g. CCF or CCP in SEM 3 when
no external EXSYNC is present.
Error 07: Camera
settings not saved>
Indicates that user settings have been corrupted by turning off the
power while executing the WUS command. Must build up new settings
from factory and re-save with WUS.
Also present during manufacturing before settings saved for first time.
Error 08: Unable to
calibrate - tap
outside ROI>
Cannot calibrate a tap that is not part of the end of line statistics.

Table of Contents