Danaher Motion Kollmorgen Speciality Electronics Troubleshooting
SERVOSTAR CD-LITE User Manual 21
NON-FATAL ERROR CODES
Status
Display
Error Message Possible Cause Fatal Non-Fatal Error #
NO_ERROR No error was recorded * 0
UNKNOWN_COMMAND Undefined command * 20
CHECKSUM_ERROR Error on _omm.. Message
checksum (ackmode 2)
* 22
DRIVE_ACTIVE Drive needs to be inactive
for the requested command
or variable
* 23
VALUE_OUT_OF_RANGE Variable value out of range * 25
SYNTAX_ERROR Communication message
syntax error
* 28
NOT_PROGRAMMABLE Variable is read-only * 36
CONFIG_FAIL_CURRENT CONFIG failed due to
current loop design failure
* 37.01
CONFIG_FAIL_MENCOFF CONFIG failed due to
MENCOFF
* 37.03
CONFIG_FAIL_MSPEED CONFIG failed due to
MSPEED
* 37.04
VEL_CONFIG_FAILED The velocity loop can’t be
con-figured with given
parameters
* 41
ARGUMENT_NOT_BINARY Variable argument must be a
power of 2
* 46
BURNIN_ACTIVE Requested function cannot
be executed during Burnin
(factory function)
* 47
BURNIN_NOT_ACTIVE Burnin (factory function)
cannot be stopped if it is not
active
* 48
NOT_AVAILABLE The requested variable value
is not available; refer to the
description of the variable in
section 1 to determine why.
* 51
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com