6. Power Connections
Dishwashers plug into standard 120 volt wall receptacles with a three pronged (grounded) plug. If the dishwasher
fails to operate properly, the power cord may be preventing power from reaching the unit.
Most problems associated with the power cord or connection are caused by damage and/or loose connections
and will likely be visible.
CAUTION: To minimize the possibility of electric shock, be certain that the wall receptacle and circuit
are properly grounded before using the dishwasher. Use of a plug adapter to adapt to a two prong outlet is
NOT recommended. Under no circumstances should you attempt to cut off or otherwise remove the third
prong (ground prong) from the power cord..
PROCEDURE
Inspecting: Power Connections
Step 1: Be sure all dishwasher Step 2: Inspect power cord at Step 3: Pull plug from receptacle with
Controls are turned off connection to receptacle. Improper a firm quick tug. Always grasp the
connection could be the sole cause plug, never pull the cord. Be careful
of trouble. Not to contact the blades of plug.
Step 4: Inspect plug carefully for Step 5: To replace cord, disconnect remove
Damaged, corroded or loose terminals. mounting screws on power cord strain relief .
Look for signs of overheating around Disconnect internal connections and install
the molded portion. If plug is damaged new cord same as original. Reassemble
replace the power cord. dishwasher and check operation.