3.12 Main Menu - Frequency Converter Information - Group 15
3.12.1 15-** Drive Information
Parameter group containing frequency converter information such as operating data, hardware configuration and software versions.
3.12.2 15-0* Operating Data
Parameter group containing operating data e.g. Operating Hours, kWh counters, Power Ups, etc.
15-00 Operating Hours
Range: Function:
0 h* [0 - 2147483647 h] View how many hours the frequency converter has run. The value is saved when the frequency
converter is turned off.
15-01 Running Hours
Range: Function:
0 h* [0 - 2147483647 h] View how many hours the motor has run. Reset the counter in par.15-07
Reset Running Hours
Counter
. The value is saved when the frequency converter is turned off.
15-02 kWh Counter
Range: Function:
0 kWh* [0 - 2147483647 kWh] Registering the power consumption of the motor as a mean value over one hour. Reset the counter
in par.15-06
Reset kWh Counter
.
15-03 Power Up's
Range: Function:
0 N/A* [0 - 2147483647 N/A] View the number of times the frequency converter has been powered up.
15-04 Over Temp's
Range: Function:
0 N/A* [0 - 65535 N/A] View the number of frequency converter temperature faults which have occurred.
15-05 Over Volt's
Range: Function:
0 N/A* [0 - 65535 N/A] View the number of frequency converter overvoltages which have occurred.
15-06 Reset kWh Counter
Option: Function:
[0] * Do not reset Select
Do not reset
[0] if no reset of the kWh counter is desired.
[1] Reset counter Select
Reset
[1] and press [OK] to reset the kWh counter to zero (see par.15-02
kWh Counter
).
NB!
The reset is carried out by pressing [OK].
3 Parameter Description ADAP-KOOL
®
Drive Programming Guide
126
MG.11.N1.02 - VLT
®
is a registered Danfoss trademark