AKD 2800
All about AKD
2800
PNU
#
Parameter
description
Factory setting 4-setup Conv.
index
Data
type
600 Operating hours No 73 7
601 Hours run No 73 7
602 kWh counter No 2 7
603 Number of cut ins No 0 6
604 Number of overtemperatures No 0 6
605 Number of overvoltages No 0 6
615 Fault log: Error code No 0 5
616 Fault log: Time No 0 7
617 Fault log: Value No 0 3
618 Reset of kWh counter No reset No 0 7
619 Reset of running hours counter No reset No 0 5
620 Operation mode Normal operation No 0 5
621 Nameplate: Unit type No 0 9
624 Nameplate: Software version No 0 9
625 Nameplate: LCP identification no. No 0 9
626 Nameplate: Database identification no. No -2 9
627 Nameplate: Power parts version No 0 9
628 Nameplate: Application option type No 0 9
630 Nameplate: Communication option type No 0 9
632 Nameplate: BMC software identification No 0 9
633 Nameplate: Motor database identification No 0 9
634 Nameplate: Unit identification for communication No 0 9
635 Nameplate: Software parts no. No 0 9
640 Software version No -2 6
641 BMC software identification No -2 6
642 Power card identification No -2 6
4-Setup:
Yes means that the parameter can be programmed
individually in each of the four Setups, i.e. one single
parameter can have four different data values. No
meansthatthedatavaluewillbethesameinallSetups.
C
onversion index:
Thisnumberreferstoaconversionfiguretobeused
when writing or reading via serial communication
with a frequency converter.
See Data character in Serial communication.
D
ata type:
Data type shows the type and length of the telegram.
Data type Description
3 Integer 16
4 Integer 32
5 Unsigned 8
6 Unsigned 16
7 Unsigned 32
9Textstring
MG.28.H2.02 -
75

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss AKD 2800 and is the answer not in the manual?

Danfoss AKD 2800 Specifications

General IconGeneral
BrandDanfoss
ModelAKD 2800
CategoryDC Drives
LanguageEnglish

Related product manuals