23
rFS Room and floor sensor•
FS Floor sensor•
RS Room sensor•
See descriptions of the possible sensor configurations in •
section 2.1.
Press to confirm.
Select the desired maximum floor temperature.
(This does not apply if the thermostat is configured to use a •
room sensor only.)
Press to confirm.
To protect the cables, the maximum floor temperature is •
factory preset to 35 °C.
Notice:
The floor temperature is measured where the sensor is
placed. The temperature of the bottom of a wooden floor
can be up to 10 degrees higher than the top. Floor manufac-
tures often specify the max. temperature on the top surface
of the floor.
Please contact your floor supplier for maximum surface
temperature.