User manual ERC 113 refrigeration controller
"ACA"
Min. no
Max. yes
Default yes
Auto Clear of Alarm/Error/ACA
If this parameter is set to "nO":
The alarm status will not disappear automatically even if the condition
which caused the alarm is no longer valid or present.
If set to "yES":
As soon as the condition which caused the alarm is no longer valid or
present, the alarm status will automatically change back to inactive.
There will be no trace of the alarm having occurred.
In general, glass door merchandise applications will be set to "yES" and
commercial fridges and freezers set to "nO".
For example, if the temperature goes too high for a period there may
be food safety considerations in a freezer containing food but not in a
fridge with cold drinks.
AHC Automatic Heater settings
Automatic Heater Control applies reverse cooling mode
(heating) to your refrigeration appliance.
This feature requires:
A) that your appliance is exposed to ambient temperatures
below the desired temperature in your cabinet
(e.g. very cold climates and outdoor use).
B) a special heater (for example a large defrost heater) built in
to your appliance.
"AuH"
Min. no
Max. yes
Default no
Automatic Heater Mode Enable
This setting is normally set to "no".
When set to "yES", parameters "End" and "Hdi" apply.
"End"
Min. 0 min
Max. 360 min
Default 60 min
Energy Mode Delay
This is the delay in minutes between the heater and the compressor
operation. The heater is not allowed to start until this number of minutes
has expired after the compressor has cut out and vice versa.
"AHS"
Min. -100.0°C
Max. 200.0°C
Default 2.0°C
Auto Heat set point
Set point of auto heating.
"AHd"
Min. 0.0 K
Max. 20.0 K
Default 2.0 K
Auto heat differential
Thermostat differential for auto heatting.
ECS ECO strategy
NOTE: some of these parameters require the installation of the
Danfoss Ambient Light Sensor. The Danfoss USB Gateway in combination
with "Software tool" allows for real time measurement of the current
light intensity. Danfoss recommends testing and adjusting "SLd" and "SLn"
values according to customers’ specific needs.
"ECo"
Min. no
Max. yes
Default Yes
ECO ON/OFF
ECO active or not. If no all other settings are not active.
"EdA"
Min. 1
Max. 10
Default 1
Door Actions
Times of door action to trigger exiting ECO
(Can only be accessed by Danfoss)
"EPA"
Min. 1
Max. 10
Default 1
Pir Actions
Times of "PIR" action to trigger exiting ECO
(Can only be accessed by Danfoss).
Produced by Danfoss A/S (ADAP-KOOL®) | 2016-07
15
DKRCC.ES.RL0.F5.02

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss ERC 113C and is the answer not in the manual?

Danfoss ERC 113C Specifications

General IconGeneral
BrandDanfoss
ModelERC 113C
CategoryController
LanguageEnglish

Related product manuals