Technical Information KPP PPU
11029257 • Rev BB • July 2013 9
**Do not attempt to apply a quadrature output PPU without rst consulting with a Sauer-
Danfoss eld applications engineer for specic application requirements.
KPP X X X X XX
Hall eect PPU
Revision
Mechanical conguration (housing)
1 Flat end
2 Conical end
3 Conical end, xed position
4 Flat end, xed position
Electrical conguration
2 Regulated supply 4.5 to 8.5 Vdc, 3 connection,
non-directional, wire fault detection
3 Regulated supply 4.5 to 8.5 Vdc, 4 connection, directional,
wire fault detection, low current
4 Regulated supply 4.5 to 8.5 Vdc, 4 connection, directional,
wire fault on speed signal, open collector on direction signal
5 Regulated supply 4.5 to 8.5 Vdc, 4 connection, directional wire
fault detection, high current, ltered speed output
6 Battery supply 7 to 32 Vdc, 3 connection, non-directional,
limited wire fault detection
7 Regulated supply 4.5 to 8.5 Vdc, 4 connection, directional,
wire fault detection, low current, quad output**
8 Regulated supply 4.5 to 8.5 Vdc, 4 connection, directional,
wire fault detection, low current, output signal divided by 2
9 Regulated supply 4.5 to 8.5 Vdc, 4 connection, directional,
wire fault detection, high current, quad output**
A Battery supply 7 to 32 Vdc, 4 connection, directional, limited
wire fault detection, high current, quad output**
B Regulated supply 4.5 to 8.5 Vdc, 3 connection, non-
directional, wire fault detection, high current, ltered speed
output
Electrical connector
1 Amp Mate-n-Lok
4
1
Delphi/Packard Weather-Pack (3 pin)
2
Delphi/Packard Weather-Pack (4 pin), used when direction signal is required
5 Delphi/Packard Metri-Pack
6 Integral Turck Eurofast (no leadwires)
7
1
Deutsch DT04 (3 pin)
2
Deutsch DT04 (4 pin), used when direction signal is required
8 Delphi/Packard Metri-Pack 150 series plug
9 Delphi/Packard Metri-Pack 150 series jack
All leadwire length is described in inches unless denoted with m (meters)
Specialties
A Special connector pinouts
B Special connector pins
Ordering Nomenclature

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss KPP Pulse Pickup and is the answer not in the manual?

Danfoss KPP Pulse Pickup Specifications

General IconGeneral
BrandDanfoss
ModelKPP Pulse Pickup
CategoryAccessories
LanguageEnglish

Related product manuals