Danfoss Link™ CC Central Controller
Installation Guide
www.danfoss.com
Question and Answer IconNeed help?

Do you have a question about the Danfoss Link CC and is the answer not in the manual?

Danfoss Link CC Specifications

General IconGeneral
TypeCentral Controller
Communication ProtocolZigbee
CommunicationWireless
Protection ClassIP21
Operating Temperature0°C to 40°C

Summary

Quick guide for installation

Introduction

Guidelines for installation

Correct installation plan

Ensures optimal wireless performance by avoiding metal objects, central placement, and shortest signal paths.

Incorrect installation plan

Highlights common errors like metal obstructions, decentral placement, and diagonal wall crossing affecting signals.

How and when to use repeater units

Defines repeater unit purpose and criteria for use, considering wall types, distances, and signal strength.

Where to place repeater units

Visual guide for optimal repeater placement to maximize signal strength in single and multi-floor building layouts.

Installation

Adding devices to the system

Details adding devices to the Danfoss Link system, specifying distance limits and using a BSU tool for setup.

Connecting power, setting country, language and datetime

Guides initial setup: connecting power and configuring regional settings like country, language, and time.

Starting up the installation menu

Explains accessing the installation menu via the cover removal and SETUP pin press for 3 seconds.

Mounting mains powered devices

Covers mounting mains-powered devices and repeaters, emphasizing powering them up before pairing for network connection.

Adding service devices

Describes adding various service devices like repeaters and controllers to the Danfoss Link system.

Mounting battery operated room devices

Details creating rooms and adding battery-operated room devices to their assigned locations in the system.

Creating rooms

Explains creating rooms and adding devices step-by-step, recommending a sequential approach for setup.

Adding room devices

Focuses on configuring room devices for temperature regulation, ensuring correct signal paths as per installation plan.

Performing a network test

Outlines conducting a network test post-installation to verify stable communication between all connected devices.

Finalising installation

Describes the final step of closing the installation process by pressing the SETUP pin.

Modifying an existing installation

Adding devices to an existing room

Explains adding new devices to an existing room and the necessity of a network test post-modification.

Changing parameters for Heat Regulations

Details adjusting heat regulation settings such as forecasting, max floor temp, and regulation type.

Removing a room or service device from the network

Provides methods for removing devices from the network via button press or backup setup menu procedures.

Factory reset of Danfoss Link CC

Describes resetting the Danfoss Link CC to factory settings, removing all rooms and devices from the network.

Wi-Fi and App connection

Connect to Wi-Fi

Details connecting the Danfoss Link CC to a Wi-Fi network, including network selection and password entry.

Connect to App

Guides connecting the Danfoss Link CC to a smart device using the Danfoss Link App from app stores.

Edit connected devices

Explains how to remove specific connected devices from the system without resetting all remote settings.

Upgrading software version

Warnings

Alert icons

Illustrates alert icons on the standby screen, explaining their meanings like battery warnings and device status.

Technical specifications and approvals

Disposal instructions

Related product manuals