Danfoss AK-CC 550A User Manual

Danfoss AK-CC 550A
36 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Controller for appliance control
AK-CC 550A
User Guide
ADAP-KOOL® Refrigeration control systems

Other manuals for Danfoss AK-CC 550A

Question and Answer IconNeed help?

Do you have a question about the Danfoss AK-CC 550A and is the answer not in the manual?

Danfoss AK-CC 550A Specifications

General IconGeneral
DisplayLCD
Digital Inputs6
Relay Outputs2
EnclosurePlastic
MountingDIN rail
Analog Inputs4
Housing MaterialPlastic
Protection ClassIP20
Communication ProtocolsModbus RTU
Output Current2 A
Operating Temperature-20°C to +50°C
Storage Temperature+70 °C

Summary

Introduction

Application

Complete refrigeration appliance control with great flexibility.

Applications

Application 1-8

Standard applications for appliances/rooms with one valve, one evaporator.

Operation

Liquid injection

Control of the electronic injection valve for evaporator superheat.

Temperature control

How temperature is regulated using sensors and control methods.

Defrost

Defrost methods

Describes Natural, Electric, and Hotgas defrost methods.

Defrost Details

Defrost on demand

Starting defrost based on refrigeration time or adaptive assessment.

Operation Features

Control of two compressors (application 5)

Managing two compressors for optimal capacity and runtime.

Data communication

Applications Overview

Application 1-4

Standard applications with combinations of functions/outputs.

Application Details

Application 5

Two-compressor operation for same-sized compressors.

Application 9

Two refrigeration sections with two defrost outputs.

Application 10

Two refrigeration sections with individual alarm/display via S3.

Survey of functions

Thermostat

Details on set point, differential, and setpoint limitation.

Start / stop of refrigeration

Manual control of refrigeration and output override.

Survey of functions - Part 2

Survey of functions - Part 3

Compressor control

Parameters for compressor operation and running times.

Defrost control

Setting defrost method and stop temperature.

Survey of functions - Part 4

Interval between defrost starts

Setting time intervals between defrost starts.

Adaptive defrosting

Setting adaptive defrost modes.

Survey of functions - Part 5

Parameter for cooling function

Superheat reference and MOP temperature settings.

Survey of functions - Part 6

Survey of functions - Part 7

Fault message

Fault message overview

Details of alarm messages and their causes.

Auxiliary schedule for settings (quick-setup)

Menu survey

Menu survey - Part 2

Menu survey - Part 3

Menu survey - Part 4

Connections

MODBUS

Connecting for MODBUS data communication.

Connections - Part 2

Data Specifications

Digital inputs

Requirements for DI1, DI2, DI3.

Ordering

Related product manuals