| Power Supply | 24 V AC / DC |
|---|---|
| Number of Inputs | 6 |
| Digital Inputs | 4 |
| Analog Inputs | 2 |
| Triac Outputs | 0 |
| Communication Protocol | Modbus RTU |
| Display | LCD |
| Enclosure | Plastic |
| Housing Material | Plastic |
| Protection Class | IP20 |
| Storage Temperature | -20°C to +70°C |
| Relative Humidity | 10% to 90% (non-condensing) |
Description of the controller's application, advantages, and basic operational principle.
Overview of the AK-CC55 controllers and their features as outlined in the portfolio table.
Summary of AK-CC55 functions based on controller type.
Diagram illustrating the various connectivity options for the AK-CC55 controllers.
Details on built-in MODBUS and optional Lon RS485 module for data communication.
Overview of the three AK-UI55 display versions: Info, Set, and Bluetooth.
List of general controller functions including day/night thermostat, adaptive controls, and inputs/outputs.
Details on liquid injection control using AKV valves, including adaptive superheat and liquid control.
How temperature control, monitoring, thermostat bands, and sensors are configured.
Configuration of thermostat bands, night setback, and temperature sensor types.
Procedures for appliance cleaning and shutdown.
Methods, sequences, start/stop conditions, and fan control during defrost.
Functions like real-time clock, coordinated defrost, melt function, rail heat, and fan pulse control.
Control of light, night blinds, and humidity.
Operating the controller remotely using system managers or service tools.
Operating the controller directly using the AK-UI55 setting display.
Using the AK-CC55 Connect app via Bluetooth for smartphone operation.
Basic controls for starting/stopping refrigeration and general configuration settings.
Parameters for thermostat control and alarm limits/delays.
Configuration settings for defrost, injection control, and fan operations.
List of alarm texts and their descriptions for error conditions.
Meaning of various controller operating status codes shown on the display.
Details on supply voltage, power consumption, sensors, and measuring accuracy.
Specifications for inputs, outputs, relays, and general function data.
Operating environment requirements and physical dimensions of the controller.
List of components, symbols, functions, and code numbers for ordering.
List of certificates, declarations, and approvals for the controller and display modules.
Information on the Danfoss Product Store, technical documentation, and local support.
Details about the AK-CC55 Connect mobile app for controller service.