AK-UI55 display menu (SW ver. 1.9x)
If the operation is protected by one or more passwords, reading and setting the parameter will be limited to:
R or W
This setting can be seen with password no. _ or higher (3 is the highest level).
This setting can be performed with password no. _ or higher (3 is the highest level).
The asterisk indicates in which application from 1-5 the parameter is applicable.
Thermostat
Table 14: Thermostat
Function
Values
R-W
Code
1
2
3
4
5
Min.value
Max.value
Fact.value
Cut-out 1
0-0
r00
*
*
*
*
*
r03
r02
2.0 °C
Dierential 1
1-2
r01
*
*
*
*
*
0.1 °C
20.0 °C
2.0 °C
Max. cut-out limit
0-2
r02
*
*
*
*
*
r03
50.0 °C
50.0 °C
Min. cut-out limit
0-2
r03
*
*
*
*
*
-60.0 °C
r02
-60.0 °C
Temperature unit
0=Celsius, 1=Fahrenheit
1-2
r05
*
*
*
*
*
0
1
0
S4 Air OFF evap. A - Adjustment
1-2
r09
*
*
*
*
*
-10.0 °C
10.0 °C
0.0 °C
S5 Evaporator A - Adjustment
1-2
r11
*
*
*
*
*
-10.0 °C
10.0 °C
0.0 °C
Main switch
-1=Manual, 0=Stop, 1=Start
0-2
r12
*
*
*
*
*
-1
1
0
Night oset
1-2
r13
*
*
*
*
*
-50.0 °C
50.0 °C
0.0 °C
Thermostat mode
1=ON/OFF, 2=Modulating,
3=ON/OFF Common
1-2
r14
*
*
*
*
*
1
3
1
Melt interval
1-2
r16
*
*
*
*
*
0 hours
10 hours
1 hour
Melt period
1-2
r17
*
*
*
*
*
0 min
30 min
5 min
S2 Gas outlet A - Adjustment
1-2
r19
*
*
*
*
*
-10.0 °C
10.0 °C
0.0 °C
Cut-out 2
0-2
r21
*
*
*
*
*
-60.0 °C
50.0 °C
2.0 °C
Air heater neutral zone
1-2
r62
*
0.0 °C
50.0 °C
5.0 °C
Air heater start delay
1-2
r63
*
0 min
240 min
240 min
Food type
0=None, 1=Vegetables, 2=Dairy,
3=Meat and sh, 4=Frozen food,
5=Ice cream
1-2
(1)
r89
*
*
*
*
*
0
5
0
Dierential 2
1-2
r93
*
*
*
*
*
0.1 °C
20.0 °C
2.0 °C
Thermostat sensor
1=Ther. air A, 2=Average all,
3=Maximum all
1-2
r99
*
*
*
*
1
3
1
(1)
In order to change this parameter the regulation must be stopped via the parameter r12 Main switch = OFF.
(1)
In order to change this parameter the regulation must be stopped via the parameter r12 Main switch = OFF.
Alarm settings
Table 15: Alarm settings
Function
Values
R-W
Code
1
2
3
4
5
Min.value
Max.value
Fact.value
Alarm delay A
1-2
A03
*
*
*
*
*
0 min
240 min
30 min
Door open alarm delay
1-2
A04
*
*
*
*
*
0 min
240 min
60 min
Alarm delay pulldown A
1-2
A12
*
*
*
*
*
0 min
240 min
90 min
High alarm limit 1
1-2
A13
*
*
*
*
*
-60.0 °C
50.0 °C
8.0 °C
Low alarm limit 1
1-2
A14
*
*
*
*
*
-60.0 °C
50.0 °C
-30.0 °C
High alarm limit 2
1-2
A20
*
*
*
*
*
-60.0 °C
50.0 °C
8.0 °C
Low alarm limit 2
1-2
A21
*
*
*
*
*
-60.0 °C
50.0 °C
-30.0 °C
Alarm delay DI 1
1-2
A27
*
*
0 min
240 min
30 min
Alarm delay DI 2
1-2
A28
*
*
*
*
*
0 min
240 min
30 min
© Danfoss | Climate Solutions | 2022.08 BC365022028193en-000201 | 33
AK-CC55 Multi Coil

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss AK-CC55 Multi Coil and is the answer not in the manual?

Danfoss AK-CC55 Multi Coil Specifications

General IconGeneral
BrandDanfoss
ModelAK-CC55 Multi Coil
CategoryController
LanguageEnglish

Related product manuals