EasyManuals Logo
Home>Danfoss>Controller>Link CC

Danfoss Link CC User Manual

Danfoss Link CC
39 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #25 background imageLoading...
Page #25 background image
Installation Guide Danfoss Link CC
25
Danfoss Heating Solutions VISGL90N 12/2014
GB
Note! Use pincode [0044] to change between the following regulation types:
Room sensor (regulates only by room temperature) - if only Danfoss Link™ RS is
tted (hydronic oor heating) or Danfoss Link™ RS + Danfoss Link™ FT (electrical
heating).
Floor sensor (regulates only by oor temperature ) - if only Danfoss Link™ FT/S
is tted.
Combined room/oor (ensures min. oor temperature and regulates room
temperature in parallel) - Danfoss Link™ RS + Danfoss Link™ FT/S is tted.
In case of hydronic oor heating, be aware if a certain max. oor temperature is
given by the oor manufacturer. This can be assured by tting a thermostatically
controlled mixing shunt.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss Link CC and is the answer not in the manual?

Danfoss Link CC Specifications

General IconGeneral
BrandDanfoss
ModelLink CC
CategoryController
LanguageEnglish

Related product manuals