Installation Guide Danfoss Link CC
25
Danfoss Heating Solutions VISGL90N 12/2014
GB
Note! Use pincode [0044] to change between the following regulation types:
Room sensor (regulates only by room temperature) - if only Danfoss Link™ RS is
tted (hydronic oor heating) or Danfoss Link™ RS + Danfoss Link™ FT (electrical
heating).
Floor sensor (regulates only by oor temperature ) - if only Danfoss Link™ FT/S
is tted.
Combined room/oor (ensures min. oor temperature and regulates room
temperature in parallel) - Danfoss Link™ RS + Danfoss Link™ FT/S is tted.
In case of hydronic oor heating, be aware if a certain max. oor temperature is
given by the oor manufacturer. This can be assured by tting a thermostatically
controlled mixing shunt.