3. Installation - step by step
3.1 Preparation
living connect® is supplied with adapters for Danfoss RA valves
and valves with M30 x 1.5 (K) connections (014G0002), two
alkaline AA batteries and a 2 mm Allen key.
Inserting the batteries
Remove the battery cover and insert the two
batteries. Ensure that the batteries are correctly
inserted.
M must ash on the display before installation,
if this is not the case, see reinstallation mode
page 10.
3.2 Installing living connect®
1. Start by mounting the adapter.
RA
K
2. Tighten RA adapter using the 2 mm
Allen key.
Hand-tighten K adapter (max. 5 Nm).
3. Screw the thermostat onto the
adapter and tighten by hand
(max. 5 Nm).
4. Press for approx. 3 seconds to enter the function menu.