To order the unit, use the following ordering number:
Model Ordering number
PTU 025, 4 inputs 134B5925
Table 1.2 Ordering Numbers
NOTICE
The PTU 025 unit can be installed in IP55 and IP66
enclosures, and can be connected with the frequency
converter using the C-option interface. This instruction is
applicable for a frequency converter in a standard congu-
ration without any modications.
Safety Instructions
For important information about safety precautions for installation, refer to the product-specic operating guide.
WARNING
DISCHARGE TIME
The frequency converter contains DC-link capacitors, which can remain charged even when the frequency converter is not
powered. High voltage can be present even when the warning LED indicator lights are o. Failure to wait the specied time
after power has been removed before performing service or repair work can result in death or serious injury.
Stop the motor.
Disconnect AC mains and remote DC-link power supplies, including battery back-ups, UPS, and DC-link connections to
other frequency converters.
Disconnect or lock PM motor.
Wait for the capacitors to discharge fully. The minimum duration of waiting time is specied in Tab le 1. 3.
Before performing any service or repair work, use an appropriate voltage measuring device to make sure that the
capacitors are fully discharged.
Voltage [V] Minimum waiting time (minutes)
4 7 15 20 30 40
200–240 1.1–3.7 kW
(1.50–5 hp)
–5.545 kW
(7.5–60 hp)
–––
380–480 1.1–7.5 kW
(1.50–10 hp)
11–90 kW
(15–121 hp)
315–1000 kW
(450–1350 hp)
400 90–315 kW
(121–450 hp)
––
500 110–355 kW
(150–500 hp)
––
525 75–315 kW
(100–450 hp)
––
525–600 1.1–7.5 kW
(1.50–10 hp)
11–90 kW
(15–121 hp)
–––
690 90–315 kW
(100– 350 hp)
––
525–690 1.1–7.5 kW
(1.50–10 hp)
11–90 kW
(15–121 hp)
–4001400 kW
(500–1550 hp)
450–1400 kW
(600–1550 hp)
Table 1.3 Discharge Time, VLT
®
HVAC Drive FC 102
Installation Instructions
Pressure Transmitter Unit PTU 025
VLT
®
HVAC Drive FC 102
2
Danfoss A/S © 12/2017 All rights reserved. MI08A102

Other manuals for Danfoss Metasys N2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss Metasys N2 and is the answer not in the manual?

Danfoss Metasys N2 Specifications

General IconGeneral
BrandDanfoss
ModelMetasys N2
CategoryDC Drives
LanguageEnglish

Related product manuals