Option 61 - Hot Water Event - Days per week
This sets the schedule of Hot Water on/off switching 
times per week. Press + until Option 61 is displayed, 
use  V and Λ to select required setting.
24 24 Hour
5-2 Either 5+2 day or A+B days depending on user APM 
setting
7 7 Day (factory setting)
Option 70 - Keyboard disable rules
This establishes the degree of functionality of the 
keyboard available to the user. It is only active if DIL 
switch 1 is set to “Disabled”. Press + until Option 70 
is displayed, use V and Λ to select required setting.
Setting 0 Normal lock: Programming functions locked (factory 
setting)
Setting 1 Full lock: All keys are disabled
Option 71 - Random start rules (24V/230 Volt models only)
This enables a random start on power-up following 
a power cut to reduce load on the electrical network. 
Random delay is in the range of 2 - 90 seconds. Press 
+ until Option 71 is displayed, use  V and Λ to select 
required setting.
Setting 0 Disabled (factory setting)
Setting 1 Enabled
Option 72 - Owner site reference number
This enables multi-site owners to store a site 
reference number in the thermostat. Press + until 
Option 72 is displayed, use V and Λ to select 
required setting.
Setting  Any value between 00 and 99 can be set