8.3.5 Power Card in E-sized Drives
6
11
9
14
15
8
7
5
4
12
13
3
1
10
2
130BF938.10
1 FK901: SMPS fuse 9 MK101: Current sensor feedback
2 Screw (T20) 10 MK103: Connector to gate drive card
3 Current scaling card 11 MK902: Fan power card signals (MK803)
4 MK102: Ribbon cable to control card 12 MK106: Brake temperature switch input
5 MK100: Current scaling card connector 13 MK500: Customer terminals for relays 1 and 2
6 MK105: CANBUS connection to fan power card 14 MK501: Mixing fan control
7 MK104: Signal test board connector 15 MK502: EMC relay control
8 Stando (8 mm) – –
Illustration 8.5 Power Card in E-sized Drives