Q3-30 Single zone int. setpoint Q3-31 Single zone ext. setpoint Q3-32 Multi zone/adv
Parameter 20-81 PID Normal/ Inverse Control Parameter 6-25 Terminal 54 High Ref./Feedb.
Value
Parameter 20-12 Reference/Feedback Unit
Parameter 20-82 PID Start Speed [RPM] Parameter 6-26 Terminal 54 Filter Time
Constant
Parameter 20-13 Minimum Reference/Feedb.
Parameter 20-83 PID Start Speed [Hz] Parameter 6-27 Terminal 54 Live Zero Parameter 20-14 Maximum Reference/Feedb.
Parameter 20-93 PID Proportional Gain Parameter 6-00 Live Zero Timeout Time Parameter 6-10 Terminal 53 Low Voltage
Parameter 20-94 PID Integral Time Parameter 6-01 Live Zero Timeout Function Parameter 6-11 Terminal 53 High Voltage
Parameter 20-70 Closed-loop Type Parameter 20-81 PID Normal/ Inverse Control Parameter 6-12 Terminal 53 Low Current
Parameter 20-71 PID Performance Parameter 20-82 PID Start Speed [RPM] Parameter 6-13 Terminal 53 High Current
Parameter 20-72 PID Output Change Parameter 20-83 PID Start Speed [Hz] Parameter 6-14 Terminal 53 Low Ref./Feedb.
Value
Parameter 20-73 Minimum Feedback Level Parameter 20-93 PID Proportional Gain Parameter 6-15 Terminal 53 High Ref./Feedb.
Value
Parameter 20-74 Maximum Feedback Level Parameter 20-94 PID Integral Time Parameter 6-16 Terminal 53 Filter Time Constant
Parameter 20-79 PID Autotuning Parameter 20-70 Closed-loop Type Parameter 6-17 Terminal 53 Live Zero
Parameter 20-71 PID Performance Parameter 6-20 Terminal 54 Low Voltage
Parameter 20-72 PID Output Change Parameter 6-21 Terminal 54 High Voltage
Parameter 20-73 Minimum Feedback Level Parameter 6-22 Terminal 54 Low Current
Parameter 20-74 Maximum Feedback Level Parameter 6-23 Terminal 54 High Current
Parameter 20-79 PID Autotuning Parameter 6-24 Terminal 54 Low Ref./Feedb.
Value
Parameter 6-25 Terminal 54 High Ref./Feedb.
Value
Parameter 6-26 Terminal 54 Filter Time Constant
Parameter 6-27 Terminal 54 Live Zero
Parameter 6-00 Live Zero Timeout Time
Parameter 6-01 Live Zero Timeout Function
Parameter 4-56 Warning Feedback Low
Parameter 4-57 Warning Feedback High
Parameter 20-20 Feedback Function
Parameter 20-21 Setpoint 1
Parameter 20-22 Setpoint 2
Parameter 20-81 PID Normal/ Inverse Control
Parameter 20-82 PID Start Speed [RPM]
Parameter 20-83 PID Start Speed [Hz]
Parameter 20-93 PID Proportional Gain
Parameter 20-94 PID Integral Time
Parameter 20-70 Closed-loop Type
Parameter 20-71 PID Performance
Parameter 20-72 PID Output Change
Parameter 20-73 Minimum Feedback Level
Parameter 20-74 Maximum Feedback Level
Parameter 20-79 PID Autotuning
Table 6.5 Q3-3 Closed-loop Settings
How to Program
Instruction Manual
MG11F522 Danfoss A/S © 08/2014 All rights reserved. 85