Service guide
Introduction
The dehumidifier requires very little attention for trouble free running. All the necessary
safety and control functions have been built in. The fan motor(s) and the compressor
have permanent lubrication and require no particular maintenance.
Monthly service
The air inlet filter is to be cleaned once a month. The filter is placed in a stand behind
the grill in the air inlet duct. Also drip tray and outlet should be cleaned so that water
can run off freely.
Please follow this procedure to perform the monthly service:
Step
Action
1
Loosen the two screws on top of the dehumidifier
2
Dismount the front cap by lifting it up and take out the filter.
The filter is located on the rear of the front cap
3
Wash the filter in tepid soapy water or vacuum clean thoroughly.
If the filter is faulty, then replace with a new
4
Insert filter in the filter holder and attach the front cap with two screws. (From
Step 1)
Annual service
The dehumidifier should be inspected once a year. Please follow this procedure to per-
form the annual service:
Step
Action
1
Remove the front from the dehumidifier
2
Inspect the inside of the dehumidifier
3
Vacuum clean the dehumidifier to remove any dust or debris
Important: Vacuum clean the condenser thoroughly
4
Wash if necessary the lamella evaporator in tepid soapy water if it is badly
soiled