EasyManuals Logo

Dantherm CDT 30 MK III User Manual

Dantherm CDT 30 MK III
36 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #22 background imageLoading...
Page #22 background image
20
Preventive maintenance, cont.
Checklist (User)
- page 2
X
÷
Criteria
Acceptance: Start dehumidifier, check
that hour counter is working.
Acceptance: Start
dehumidifier, check
that MED
-
counter measures the power
consumption.
Acceptance: Light in display. Display is
readable.
Acceptance: Clean, free of oil and dirt.
Acceptance: Ventilation openings are free
of dust and dirt.
Acceptance: Deformation < 5 mm
deep.
Openings between plates < 5 mm.
Acceptance: No loose or missing screws.
No obvious damages on handle. The
handle slides up and down easily. The
handle cannot slide up and down, when
thumbscrews are tightened.
Acceptance: Gaskets are complete and
without any cracks.
Acceptance: Wheels run freely
without
hindrance. No obvious damages on the
track of the wheels.
How to
Visually
Visually
Visually
Visually
Visually
Visually
Measuring tape
Manual check
Visually
Visually
Frequency
Y
Y
Y
M
M
Y
Y
Y
Y
What
Does operation hour counter work?
Does the MED
-counter work?
Display
The casing of the dehumidifier
Cleaning
Free passage through ventilation open-
ings
Deformations, cracks or fractures
Fixation and damage of handle
Gaskets and sealings
Visual check of the wheels

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dantherm CDT 30 MK III and is the answer not in the manual?

Dantherm CDT 30 MK III Specifications

General IconGeneral
BrandDantherm
ModelCDT 30 MK III
CategoryDehumidifier
LanguageEnglish

Related product manuals