Identication Parameters
Index
(dec)
Parameter
Object Name
Lenght
Subindex
(o󰀨set)
Value/Range Description Data Type Access* Remark
0x0010 (16) Vendor Name 9 octets DATALOGIC Informative StringT RO
0x0011 (17) Vendor Text 19 octets Empower your vision StringT RO
0x0012 (18) Product Name 16 octets See “Device variant collection” Detailed product name StringT RO
0x0013 (19) Product ID 5 octets See “Device variant collection” Product identication StringT RO
0x0014 (20) Product Text 22 octets See “Device variant collection” StringT RO
0x0015 (21) Serial Number 9 octets Unique serial number StringT RO
0x0016 (22)
Hardware
Revision
5 octets RevAE StringT RO
0x0017 (23)
Firmware
Revision
5 octets 1.0.1 StringT RO
0x0018 (24)
Application
Specic Tag
32 octets *** (default) Tag application dened by user StringT R/W Saved in non-volatile memory
0x0019 (25) Function Tag 32 octets *** (default) Additional tag for device function identication StringT R/W Saved in non-volatile memory
0x001A (26) Location Tag 32 octets *** (default) Additional tag for device function identication StringT R/W Saved in non-volatile memory
Observation / Diagnostic Parameters
Index
(dec)
Parameter
Object Name
Lenght
Subindex
(o󰀨set)
Value/Range Description Data Type Access* Remark
0x0028 (40)
Process Data
Input
1 octet Read last valid Process Data Input from PDin channel
Device
specic
RO
0x0041 (65) Analog Signal 2 octets Read analog signal UIntegerT RO
0x0052 (82)
Device
Temperature
2 octets
2 octets
2 octets
2 octets
2 octets
1(64)
2(48)
3(32)
4(16)
5(0)
Device temperature actual
Device min. temperature since powerup
Device max. temperature since powerup
Device min. temperature during lifetime
Device max. temperature during lifetime
IntegerT
IntegerT
IntegerT
IntegerT
IntegerT
RO
RO
RO
RO
RO
0x0053 (83)
Device
Temperature
Threshold
2 octets
2 octets
1(16)
2(0)
Device min. temperature threshold
Device max. temperature threshold
IntegerT
IntegerT
R/W
Saved in non-volatile memory every
hour. Events are generated if the
device temperature exceeds the
thresholds.
0x0057 (87) Operating Hours
4 octets
4 octets
4 octets
1(64)
2(32)
3(0)
0...(2^32)-1
Operating Hours: device operating hours. Not resettable by user.
Operating Hours Maintenance: device operating hours, reset on
system command “Conrm Maintenance”.
Operating Hours Power Up: Time in hours since power up.
UIntegerT
UIntegerT
UIntegerT
RO
RO
RO
0x0024 (36) Device Status 1 octet
0x00 → Device is operating properly
0x01 → Maintenance Required
0x02 → Out of specification
0x03 → Functional Check
0x04 → Failure
Contains current status of the device UIntegerT RO
0x0025 (37)
Detailed Device
Status
3 octets
Information about currently pending Events.
Implemented as dynamic list.
UIntegerT RO
0x0051 (81) Emitter Status 1 octet
0x00 = Emitter OFF
0x01 = Emitter ON
Contains current statuts of the emitter BooleanT RO
0x0059 (89) RGB selection 1 octet
0x01 = Red emission
0x02 = Green emission
0x03 = Blue emission
Select emission type UIntegerT R/W Saved in non-volatile memory
*RO = read only, WO = write only, R/W = read/write