References
292
PowerScan™ PD9531-AR/PBT9501-AR/PM9501-AR
Global Prefix/Suffix
Up to 20 ASCII characters may be added as a prefix (in a position before the 
bar code data) and/or as a suffix (in a position following the bar code data) 
as indicated in Figure 8.
Figure 8. Prefix and Suffix Positions
Prefix SuffixAIM IDLabel ID Label IDBar Code Data
00 - 20 Characters (ASCII)
AND
OR
OR...
Example: Setting a Prefix
In this example, we’ll set a prefix for all symbologies.
1. Determine which ASCII character(s) are to be added to scanned bar 
c
ode data. In this example, we’ll add a dollar sign (‘$’) as a prefix. 
2. Go to page 54 and scan the ENTER/EXIT PROGRAMMING MODE bar 
code, then scan the SET GLOBAL PREFIX bar 
code.
3. Reference the ASCII Chart on the inside back cover of this manual to 
find the hex value assigned to the desired character. The corresponding 
hex num
ber for the ‘$’ character is 24. To enter this selection code, 
scan the ‘2’ and ‘4’ bar codes from Appendix D, Keypad.
If you make a mistake before the last character, scan the CANCEL 
bar code to abort and not save the entry string. You can then start 
again at the beginning.
4. If less than the expected string of 20 characters are selected, scan the 
ENTER/EXIT bar code to terminate the string.
5. Scan the ENTER/EXIT bar code once again to exit Programming Mode.
6. The resulting message string would ap
pear as follows: 
Scanned bar code data: 12345 
Resulting message string output: $12345