Operating Modes
16 PowerScan™ PD9531-AR
Operating Modes
Scan Mode
The imager can be set to operate in one of several scan-
ning modes. See the PRG for more information and set-
tings for any of the options:
Trigger Single (Default) —
This mode is associated with typi-
cal handheld reader operation. When the trigger is pulled,
illumination is turned on and the scanner attempts to
read a label. Scanning is activated until one of the follow-
ing occurs:
• the programmable “maximum scan on time”
1
has elapsed
• a label has been read
•the trigger is released
Trigger Pulse Multiple —
Scanning begins when the trigger
is pulled and continues after the trigger is released, until
the trigger is pulled again or until the programmable
“maximum scan on time”
1
has elapsed. Reading a label
does not disable scanning. Double Read Timeout
1
pre-
vents undesired multiple reads while in this mode.
Trigger Hold Multiple —
When the trigger is pulled, scan-
ning starts and the product scans until the trigger is
released or “maximum scan on time”
1
has elapsed. Read-
ing a label does not disable scanning. Double Read Time-
out
1
prevents undesired multiple reads in this mode.
Always On —
The illuminator is always ON and the reader
is always ready for code reading. Double Read Timeout
1
prevents undesired multiple reads.
Flashing —
The reader illuminator flashes on and off
regardless of the trigger status. Code reading takes place
only during the Flash On
2
time. Double Read Timeout
1
prevents undesired multiple reads.
1. See the Product Reference Guide (PRG) for these and
other programmable features
2. Controlled by Flash On Time and Flash Off Time. Use