Cradle Default Configuration
Quick Reference Guide 23
Cradle Default Configuration
USB DEFAULT SETTINGS
DATA FORMAT: code identifier disabled, code length not transmitted, character
replacement disabled, address stamping disabled, address delimiter disabled.
USB KEYBOARD: USA keyboard, FIFO enabled, inter-character and inter-code
delays disabled.
USB COM: handshaking disabled, delay disabled, rx timeout 5 sec., ack/nack
disabled, FIFO enabled, serial trigger lock disabled.
Default Headers and Terminators for each USB mode:
- USB-KBD: no header, terminator = ENTER
- USB-KBD-ALT-MODE: no header, terminator = CR
- USB-COM: no header, terminator = CR-LF
- USB-IBM-TABLE TOP: not applicable
- USB-IBM-HAND HELD: not applicable
RS-232 Standard DEFAULT SETTINGS
9600 baud, no parity, 8 data bits, 1 stop bit, handshaking disabled, ACK/NACK
disabled, FIFO enabled, inter-character delay disabled, 5 sec. rx timeout, serial
trigger lock disabled.
DATA FORMAT: code identifier disabled, code length not transmitted, no
header, terminator = CR-LF, character replacement disabled, address
stamping disabled, address delimiter disabled.
RS-232 Nixdorf DEFAULT SETTINGS
9600 baud, odd parity, 8 data bits, 1 stop bit, handshaking hardware (RTS/
CTS), ACK/NACK disabled, FIFO disabled, inter-character delay disabled, 9.9
sec. rx timeout, serial trigger lock disabled.
DATA FORMAT: code identifier enabled, code length not transmitted, no
header, terminator = CR, character replacement disabled, address stamping
disabled, address delimiter disabled.
RS-232 Fujitsu DEFAULT SETTINGS
9600 baud, no parity, 8 data bits, 1 stop bit, handshaking disabled, ACK/NACK
disabled, FIFO enabled, inter-character delay disabled,
2 sec. rx timeout, serial trigger lock disabled.
DATA FORMAT: code identifier enabled, code length not transmitted, no
header, terminator = CR, character replacement disabled, address stamping
disabled, address delimiter disabled.
RS-232 ICL DEFAULT SETTINGS
9600 baud, even parity, 8 data bits, 1 stop bit, handshaking RTS always on,
ACK/NACK disabled, FIFO enabled, inter-character delay disabled,
9.9 sec. rx timeout, serial trigger lock disabled.

Other manuals for Datalogic QuickScan Mobile

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datalogic QuickScan Mobile and is the answer not in the manual?

Datalogic QuickScan Mobile Specifications

General IconGeneral
BrandDatalogic
ModelQuickScan Mobile
CategoryBarcode Reader
LanguageEnglish

Related product manuals