48 QS2500
Code 11
Read: Format:
Checksum Verification: The checksum is presented as the sum mod 11 of all
data digits.
Checksum Transmission: When this option is enabled, the QS2500 will
transmit one-digit or two-digit checksums, depending upon the setting
for checksum verification.
Maximum/Minimum Code Length: Same as Code 39. See page 35.
Truncate Leading/Ending: Same as UPC-A. See page 27.
Code ID Setting: Same as UPC-A. See page 27.
Insertion Group Selection: Same as UPC-A. See page 27.
Data Digits
(Variable)
Checksum1
(Optional)
Checksum1
(Optional)
Option Bar Code Option
Alphanumeric
Entry
Read
Disable 00*
Enable 01
Checksum Verification
Disable 00
One digit 01*
Two digit 02
Checksum Transmission
Disable 00*
Enable 01
Max. Code Length
Use Global Max. 00*
1–64 01–64
Start Program