ISO MAX V Manual – v. 1.2 – july 2012 29
10.1.31 Sets the shutdown timeout
• Command syntax: “.ST##”[CR]
• Command answer: [LF]
• Command action: sets the shutdown timeout in minutes
• Parameter range: ##= 1 to 5.
Description: this command sets the shutdown timeout in minutes.
10.1.32 Gets the shutdown timeout
• Command syntax: “?ST##”[CR]
• Command answer: [CR][LF] ”ST=##” [CR][LF]
• Command action: gets the shutdown timeout in minutes
• Parameter range: ##= 1 to 5.
Description: this command gets the shutdown timeout in minutes.
10.1.33 Sets the VCP baud rate
• Command syntax: “.SB#”[CR]
• Command answer: [LF]
• Command action: sets the shutdown timeout in seconds
• Parameter range: #= 0 to 4.
0= 9600 baud
1= 19200 baud
2= 38400 baud
3= 57600 baud
4= 115200 baud
Description: this command sets the VCP baud rate.
10.1.34 Gets the VCP baud rate
• Command syntax: “?SB#”[CR]
• Command answer: [CR][LF] ”SB=#” [CR][LF]
• Command action: gets the current VCP baud rate
• Parameter range: #= 0 to 4.
Description: this command gets the VCP baud rate.
10.1.35 Sets the “auto shutdown” function
• Command syntax: “.ES#” [CR]
• Command answer: [LF]
• Command action: sets the “auto shutdown” function
• Parameter range: #= 0 or 1.
Description: this command sets the auto shutdown function.
1: enable function. 0: disable function.
10.1.36 Gets the “auto shutdown” function status
• Command syntax: “?ES” [CR]
• Command answer: [CR][LF] ”ES=#” [CR][LF]
• Command action: gets the “auto shutdown” function status
• Parameter range: #= 0 or 1.
Description: this command returns the key beep function status.
10.1.37 Firmware update function
• Command syntax: “.uF” [CR]
• Command answer: [LF]