ISO MAX V Manual – v. 1.2 – july 2012 28
10.1.25 Sets the “reading beep” function
• Command syntax: “.RB#” [CR]
• Command answer: [LF]
• Command action: sets the “reading beep” function
• Parameter range: #= 0 or 1.
Description: this command sets the reading beep function.
1: enable function. 0: disable function.
10.1.26 Gets the “reading beep” function status
• Command syntax: “?RB” [CR]
• Command answer: [CR][LF] ”RB=#” [CR][LF]
• Command action: gets the “reading beep” function status
• Parameter range: #= 0 or 1.
Description: this command returns the reading beep function status.
10.1.27 Sets the “key beep” function
• Command syntax: “.KB#” [CR]
• Command answer: [LF]
• Command action: sets the “key beep” function
• Parameter range: #= 0 or 1.
Description: this command sets the key beep function.
1: enable function. 0: disable function.
10.1.28 Gets the “key beep” function status
• Command syntax: “?KB” [CR]
• Command answer: [CR][LF] ”KB=#” [CR][LF]
• Command action: gets the “key beep” function status
• Parameter range: #= 0 or 1.
Description: this command returns the key beep function status.
10.1.29 Sets the reading timeout
• Command syntax: “.RT##”[CR]
• Command answer: [LF]
• Command action: sets the reading timeout in seconds
• Parameter range: ##= 1 to 99.
Description: this command sets the reading timeout in seconds.
10.1.30 Gets the reading timeout
• Command syntax: “?RT##”[CR]
• Command answer: [CR][LF] ”RT=##” [CR][LF]
• Command action: gets the reading timeout in seconds
• Parameter range: ##= 1 to 99.
Description: this command gets the reading timeout in seconds.