32 E-4203/E-4204/E-4304
Problem Possible Cause Solution
Label Alignment is
incorrect. Pressing
FEED successively
results in a short
label length, one-
inch.
Label Alignment
Length is not
correct. The
default Label
Alignment Length is
1.00”, and will
result in this
behavior when any
larger label length
is used without
setting the
appropriate length.
¾ Set Label Alignment to
AUTO. Press and hold FEED
until paper moves for
automatic Label Alignment
Length measurement.
~OR~
¾ Measure the label length and
use the Setup Menu to set the
new length. Print a Database
Configuration label to ensure
the new length has been set.
Label Alignment is
incorrect. Pressing
FEED successively
results in a label
length longer than
actual, one-inch.
Label Alignment
Length is not
correct. The
default Label
Alignment Length is
1.00”, and will
result in this
behavior when any
larger label length
is used without
setting the
appropriate length
¾ Set Label Alignment to
AUTO. Press and hold FEED
until paper moves for
automatic Label Alignment
length measurement.
~OR~
¾ Measure the label length and
use the Setup Menu to set the
new length. Print a Database
Configuration label to ensure
the new length has been set.