A
B
5 INSTALLATION
5.1 Placing and maintenance
Only qualified employees are allowed to install the machine.
The machine can only be used for its purpose: to divide and round dough.
Guarantee can not be claimed if changes have been made to the machine without the
manufacturers permission and/or if not-original spare parts are used. The use of not-
original spare parts can damage the machine and/or harm the operator.
The machine should be placed on a solid and flat floor. The machine is very stable. In case of a very
slippery floor, you can block the wheels by using wedges.
Check if the rounding plates which are delivered with the
machine fit well. The hole in the plate should fall easily over the
locking pin (see figure 5-1, B) of the rounding table.
If not, plane the back of the plate until it does fall easily over it.
Figure 5-1
5.2 Conditions
Temperature: 15 C to 40 C
Relative humidity: 20% to 95%
5.3 Electrical connection
A qualified engineer must carry out the installation and an electrician
should connect the machine to the power supply. Always check first if
the voltage and the phases of the electrical connection are in
accordance with those of the machine (see machine plate). If this is not
the case, please contact your supplier.
Check the direction of rotation of the machine. Turn the power switch
(see figure 2-3) to position 1 and press the rounding handle (see figure
5-2, B). The rounding table will make a rotation movement
counterclockwise. If this is not the case, an electrician should change
the two phases in the plug in order to change the direction of rotation
of the motor.
Figure 5-2
B