Setup Mode
15
1. Press the < and > keys to move from one numeral to another.
2. Press the + and - keys to adjust a numeral up or down.
3. To switch between feet and meters, press 2ND then press UNITS.
4. If you are below sea level, like in Death Valley or the Salton Sea, first enter the ele-
vation as a positive number. Then, select the “0” immediately to the left of the left-
most non-zero digit (the second zero from the left in 0026, for example, or the first
zero from the left in 0207) and press the + and - keys to switch from a positive to
negative elevation.
Note: You can only set the elevation to negative after you have entered a non-zero digit
and when the zero in the position immediately to the left of the left-most non-zero
digit has been selected.
5. Press DONE to move to the next screen.
Screen 11: Wind Cup Size
Vantage Pro2 stations come standard with large wind cups. Switch this setting to
SMALL CUP if you have separately purchased and installed small wind cups. Switch
to OTHER if you are receiving from a Vantage Vue ISS or are using a third-party ane-
mometer.
Note: Large wind cups are more sensitive to low wind speeds and are the best choice for
most users.
Screen 11: Wind Cup Size
1. Press the + and - keys to switch between the LARGE CUP, SMALL CUP, and
OTHER wind cup settings.
2. Press DONE to move to the next screen.

Other manuals for Davis Instruments Vantage Pro2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Davis Instruments Vantage Pro2 and is the answer not in the manual?

Davis Instruments Vantage Pro2 Specifications

General IconGeneral
Update Interval2.5 seconds
Wind Direction Resolution
Wind Direction Range0 to 360°
Rain CollectorSelf-emptying tipping bucket
UV Index Range0 to 16
Solar Radiation Range0 to 1800 W/m²
Console DisplayLCD with backlight
Wireless Transmission Range1000 feet (300 meters) line of sight
Temperature Range-40 to 150 °F (-40 to 65 °C)
Humidity Range1 to 100%
Barometric Pressure Range16.00 to 32.50 inHg (540 to 1100 hPa)
Wind Speed Range0 to 200 mph (0 to 322 km/h)
Rain Collector Size0.01 inch (0.2 mm) resolution
Rain Measurement Accuracy±4% at rates up to 2 in/hr (50 mm/hr)
Power SupplySolar-powered with battery backup
Console Power SupplyAC adapter or 3 C batteries