Graph Mode
31
Clearing Alarm Settings
1. Press ALARM to enter alarm mode.
The ALARM and HIGHS icons appear.
2. Select the alarm setting you wish to clear.
3. Press 2ND, then press and hold CLEAR until the setting changes to all dashes.
You have cleared the alarm setting.
4. Press DONE to exit Alarm Mode.
Note: To clear all alarms, enter Alarm mode (press and release the ALARM key), then
press and hold the ALARM key until all the fields become dashed.
Silencing Alarms
1. Press DONE to silence an alarm when it sounds.
Graph Mode
The Vantage Pro2 console includes a powerful Graph Mode that allows you to view
over 100 graphs of different kinds right on the screen, all without connecting to a per-
sonal computer.
Viewing Graphs
Although the graphs available may vary for each weather variable, you display the
graphs in the same way.
1. Select a variable to graph.
Only the date, graph, graph icon,
and selected variable are visible.
The rest of the screen is blank.
2. Press GRAPH to enter Graph
Mode.
Values for the each of the last 24
hours are displayed in the graph,
each hour represented by a dot.
The dot at right end of the graph is the value for the current hour. You’ll notice that
the dot is blinking.
3. Press the < key and the second dot from the right starts to blink.
The screen displays the new dot’s value. The time display shows what hour of the
last 24 is being viewed.
4. Press the < and > keys to view the variable’s values for each of the last 24 hours. The
console also displays the maximum and minimum temperatures recorded in the last
24 hours.
5. Press the + and - keys to shift the graph’s time span.
GRAPH
Vertical Scale: 2
TEMP OUT
F
am
Last 24 hrs
hr
Every 1

Other manuals for Davis Instruments Vantage Pro2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Davis Instruments Vantage Pro2 and is the answer not in the manual?

Davis Instruments Vantage Pro2 Specifications

General IconGeneral
Update Interval2.5 seconds
Wind Direction Resolution
Wind Direction Range0 to 360°
Rain CollectorSelf-emptying tipping bucket
UV Index Range0 to 16
Solar Radiation Range0 to 1800 W/m²
Console DisplayLCD with backlight
Wireless Transmission Range1000 feet (300 meters) line of sight
Temperature Range-40 to 150 °F (-40 to 65 °C)
Humidity Range1 to 100%
Barometric Pressure Range16.00 to 32.50 inHg (540 to 1100 hPa)
Wind Speed Range0 to 200 mph (0 to 322 km/h)
Rain Collector Size0.01 inch (0.2 mm) resolution
Rain Measurement Accuracy±4% at rates up to 2 in/hr (50 mm/hr)
Power SupplySolar-powered with battery backup