Setup Mode
17
Note: This setting determines when the yearly rain total is reset to zero. Davis Instruments
recommends a January rain season setting (the default), unless you reside in the
west coast of the United States, the Mediterranean coast, experience dry winters in
the Southern Hemisphere. If so, change the rain season setting to July 1
st
. If you are
performing hydrology studies in any of these climates in the Northern Hemisphere,
change the rain season setting to October 1
st
.
Screen 14: Serial Baud Rate
The Baud Rate screen displays only if the console detects that a WeatherLink data log-
ger installed on the console.
The console uses a serial or USB port to communicate with a computer. If you are con-
necting the console directly to your computer via USB or Ethernet, leave the setting at
19200, the highest rate for the port. If you’re using a modem, use the highest setting
your modem can handle. The console must be equipped with a WeatherLink data log-
ger to communicate with a computer or modem.
Screen 14: Baud Rate
Note: The baud rate setting on your console must match the baud rate of the software you
are using. If you are using WeatherLink for Vantage Pro2, refer to WeatherLink help
for instructions on setting the serial port baud rate on your computer.
1. Press the + and - keys to select the baud rate.
Your Vantage Pro2 console supports baud rates of 1200, 2400, 4800, 9600, 14400,
and 19200.
2. You have completed the console setup. To exit Setup Mode, press and hold DONE
until the current weather screen appears.
Clear All Command
After you have completed the above setup procedures and have exited the Setup Mode,
please use the Clear All command before putting your weather station into service.
The Clear All command clears all stored high and low weather data including monthly
and yearly highs and lows and clears the alarm settings. The command is recommended
to properly clear the console of any erroneous data before first putting the station into
use.
1. Make sure wind speed is showing in the wind compass. If wind direction is showing,
press WIND on the console until wind speed appears.
2. Press 2ND, then press and hold CLEAR for at least six seconds.
3. Release CLEAR when you see “CLEARING NOW” displayed at the bottom of the
console’s screen.

Other manuals for Davis Instruments Vantage Pro2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Davis Instruments Vantage Pro2 and is the answer not in the manual?

Davis Instruments Vantage Pro2 Specifications

General IconGeneral
Update Interval2.5 seconds
Wind Direction Resolution
Wind Direction Range0 to 360°
Rain CollectorSelf-emptying tipping bucket
UV Index Range0 to 16
Solar Radiation Range0 to 1800 W/m²
Console DisplayLCD with backlight
Wireless Transmission Range1000 feet (300 meters) line of sight
Temperature Range-40 to 150 °F (-40 to 65 °C)
Humidity Range1 to 100%
Barometric Pressure Range16.00 to 32.50 inHg (540 to 1100 hPa)
Wind Speed Range0 to 200 mph (0 to 322 km/h)
Rain Collector Size0.01 inch (0.2 mm) resolution
Rain Measurement Accuracy±4% at rates up to 2 in/hr (50 mm/hr)
Power SupplySolar-powered with battery backup
Console Power SupplyAC adapter or 3 C batteries

Related product manuals