EasyManuals Logo

Davis Instruments Vantage Pro2 User Manual

Default Icon
56 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #53 background imageLoading...
Page #53 background image
Weather Data Specifications
50
Solar Radiation Solar sensor 1 W/m
2
0 to 1800 W/m
2
5% of full scale
Inside
Temperature
Included in
Console
0.1F; 0.1C
+32 to +140F;
0 to +60C
1F; 0.5C
Outside
Temperature
***
ISS, Temp
Station or Temp
Hum Station
0.1F; 0.1C
-40 to +150F;
-40 to +65C
1F; 0.5C
Extra Temperature
ISS, Temp
Station, Temp
Hum Station,
Leaf Soil Station
or Soil Station
1F; 1C
-40 to +150F
-40 to +65C
1F; 0.5C
Heat Index
ISS or Temp/
Hum Station
1F; 1C
-40to +165F;
-40 to +74 C
3F (1.5C)
Temp-Hum-Sun-
Wind index
(THSW)
ISS & Solar
Radiation
1F; 1C
-90 to +165F;
-68 to +74 C
4F (2C)
Time
Included in
Console
1 min 24 hours 8 sec./mon.
Date 1 day month/day 8 sec./mon.
UV Index
UV Radiation
0.1 Index 0 to 16 5% of full scale
UV Dose
0.1 MED < 20,
1 MED > 20
0 to 199 MEDs 5%
Wind Direction
Anemometer
1 0 to 360 3
Compass Rose 22.5 16 compass pts 0.3 compass pt
Wind Speed (large
cups)
1 mph; 1 kt; 0.4 m/
s; 1 km/h
2 to 180 mph;
2 to 156 kts
3 to 290 km/h,
1 to 80 m/s
greater of
2 mph/kts;
1 m/s; 3 km/h
or 5%
Wind Chill ISS 1F; 1C
-110 to +135F
-79 to +57C
2F;1C
***
Outside temperature accuracy is based on the temperature sensor itself and not on the sensor and
the passive shielding together. The solar radiation induced error for standard ration shield: +4F (2C)
at solar noon; for fan aspirated radiation shield: +0.6F (0.3C) at solar noon (insolation = 1040 W/m
2
,
avg. wind speed 2 mph (1 m/s), reference: RM Young Model 43408 Fan-Aspirated Radiation
Shield).
Weather Data Specifications
Variable
Required
Sensors
Resolution Range
Nominal
Accuracy (+/-)

Other manuals for Davis Instruments Vantage Pro2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Davis Instruments Vantage Pro2 and is the answer not in the manual?

Davis Instruments Vantage Pro2 Specifications

General IconGeneral
Update Interval2.5 seconds
Wind Direction Resolution
Wind Direction Range0 to 360°
Rain CollectorSelf-emptying tipping bucket
UV Index Range0 to 16
Solar Radiation Range0 to 1800 W/m²
Console DisplayLCD with backlight
Wireless Transmission Range1000 feet (300 meters) line of sight
Temperature Range-40 to 150 °F (-40 to 65 °C)
Humidity Range1 to 100%
Barometric Pressure Range16.00 to 32.50 inHg (540 to 1100 hPa)
Wind Speed Range0 to 200 mph (0 to 322 km/h)
Rain Collector Size0.01 inch (0.2 mm) resolution
Rain Measurement Accuracy±4% at rates up to 2 in/hr (50 mm/hr)
Power SupplySolar-powered with battery backup
Console Power SupplyAC adapter or 3 C batteries

Related product manuals