43
Appendix
Specifications: Complete specifications on www.davisinstruments.com.
Temperature range: . . . . . . . . . . . . . . . . . . -40 to 150° F (-40 to 65° C)
Sensor Suite primary power: . . . . . . . . . . . Solar power – Davis solar charger
Backup power: . . . . . . . . . . . . . . . . . . . . . . CR-123A 3-volt lithium battery (8 months without
sunlight- greater than 2 years depending on solar
charging
Cabled Sensor Suite primary power: . . . . . Console cable from the Vantage Pro2 cable
Wireless Sensor Suite frequency range and power output:
Transmitter ID codes: . . . . . . . . . . . . . . . . . 8 user-selectable
License: . . . . . . . . . . . . . . . . . . . . . . . . . . . Low power (less than 8 mW), no license required
Sensor Suite Weather Variable Update Intervals
(Transmitter ID Dependent)
Wind speed: . . . . . . . . . . . . . . . . . . . . . . . . 2.5 to 3 seconds
Wind direction: . . . . . . . . . . . . . . . . . . . . . . 2.5 to 3 seconds
Accumulated rainfall: . . . . . . . . . . . . . . . . . 20 to 24 seconds
Rain rate: . . . . . . . . . . . . . . . . . . . . . . . . . . 20 to 24 seconds
Outside temperature: . . . . . . . . . . . . . . . . . 10 to 12 seconds
Outside humidity: . . . . . . . . . . . . . . . . . . . . 50 seconds to 1 minute
Ultraviolet radiation: . . . . . . . . . . . . . . . . . . 50 seconds to 1 minute
Solar radiation: . . . . . . . . . . . . . . . . . . . . . 50 seconds to 1 minute
Fan-Aspirated Radiation Shield
24-Hour Fan
Aspiration Rate
Solar-powered, full sun . . . . . . . . . . . . . 190 ft./min. (0.96m/s)
Battery only . . . . . . . . . . . . . . . . . . . . . . 80 feet/min (0.4 m/s)
Radiation Induced Temperature Error . . . . 0.5°F (0.3°C)
[At solar noon, insolation = 1040 W/m
2
]
(Reference: RM Young model 43408)
Battery Charge/Operating Temperature . . . 32° to +113°F (0° to +45°C)
Battery Discharge/Storage Temperature . . -4° to +140°F (-20° to +60°C)
Fan Primary Power. . . . . . . . . . . . . . . . . . . Solar panel
Fan Secondary Power . . . . . . . . . . . . . . . . 1 or 2 1.2 Volt NiMH C-cells
Daytime Fan
Radiation Induced Temperature Error . . . . 1°F (0.5°C)
[At solar noon, insolation = 1040 W/m
2
]
(Reference: RM Young model 43408)
Operating Temperature. . . . . . . . . . . . . . . . -40° to +150°F (-40° to +65°C)
Non-operating Temperature . . . . . . . . . . . . -50° to +158°F (-45° to +70°C)
Fan Power . . . . . . . . . . . . . . . . . . . . . . . . . Solar panel
REGION FREQUENCY RANGE & POWER OUTPUT
USA 902 - 928 MHz FHSS, <10mW
EU 868.0 - 868.6 MHz FHSS, <10mW
Australia, Brazil 918 - 926 MHz FHSS, <10mW
India
865 - 867 MHz FHSS, <10mW
New Zealand, Peru 921 - 928 MHz FHSS, <10mW
Japan 920.5 - 925.1 MHz FHSS, <1mW
Taiwan, Pakistan
920 - 925 MHz FHSS, <10mW