46
SPACE
SPACE 
XL
SPACE 
XXL
OPERATING PARAMETERS
Collectivity function: if it is activated it deactivates both opening  and closing inputs for the whole duration of automatic opening 
and closing
• 000: disabled
• 001: activated only upon opening
• 002: activated on automatic opening and closing
Unused parameter
“Reversal” mode selection (during the manoeuvre a command impulse reverse the mouvement) or “step by step” (during the 
manoeuvre a command impulse stops the mouvement). A next impulse restart the operator to the opposite direction.
• 000: “reversal function”
• 001: “step by step function”
PHOTO 1
PHOTO  input  functioning:  If=0:  photocell  enabled  while  closing  and  starting  when  the  gate  is  stopped;  if=1 
photocells are  always  enabled;  if=2  photocells  are  enabled  while    closing  only. When  enabled,  its  activation 
provokes: the inversion (while closing), the stop (while opening) and prevent the starting (when gate is closed).
If=3-4-5, the operation is the same as the values 0-1-2 but with “close immediately” enabled: in any case, during 
the opening and/or the pause time, removal of a possible obstacle causes the gate automatically closes after a 
xed delay of 2 sec.
• 000: photocell enabled while closing and when gate is stopped
• 001: photocells always enabled
• 002: photocells enabled only while closing
• 003: as 000 but with “close immediately” enabled
• 004: as 001 but with “close immediately” enabled
• 005: as 002 but with “close immediately” enabled
PHOTO 2
Operation mode selection of the warning light output:
If> 1 “courtesy light” (output ON during each movement, OFF when the motor stops, after the setting delay)
• >001 : “courtesy light” off delay
(2sec………………255sec)
Unused parameter
“soft start” function: motors accelerate gradually until they reach the set speed, avoiding sudden departures
Warning: Set the value of P054=2 only if the obstacle detection is disabled (P037 and/or P038 =100)
• 000: “soft start” deactivated
• 001: “soft start” activated
• 002: “long soft start” activated
Adjust the inversion on obstacle period (detected by internal anti-crushing sensor or by the safety input when activated): If = 0 
it makes a complete inversion, if> 0 indicates the duration (in seconds) of the run, after inversion resulting from detection of an 
obstacle during the opening.
• 000: complete reversal on obstacle
• >000: duration of reversal on obstacle 
(1sec……………..10sec)
Adjust the inversion on obstacle period (detected by internal anti-crushing sensor or by the safety input when activated): If = 0 
it makes a complete inversion, if> 0 indicates the duration (in seconds) of the run, after inversion resulting from detection of an 
obstacle during the closing.
• 000: complete reversal on obstacle
• >000: duration of reversal on obstacle 
(1sec……………..10sec)
Unused parameter
Duration adjustment for the secondary force in closing: adjusts the duration of the last part of the closing movement, in which the 
force is managed separately with P039. The value is expressed in number of revolutions of the rotor.
(0...................................255)
At every turn of the rotor, the slide moves by:
• 4,6 mm: SPACE
• 4,0 mm: SPACE XL
• 6,3 mm: SPACE XXL
Adjustment of the stop-margin in closing: adjusts the duration of the last part of the closing movement, in which an obstacle is 
seen as a stop, causing the motor to stop without reversal on the obstacle. The value is expressed in number of revolutions of 
the rotor.
(1...................................255)
Force adjustment in the stop margin in closing, its duration is set through P059. (2...................................100)
“Energy saving” mode: If=1 after 10sec  of inactivity, the control panel  turns the 24V outputs and the display off that will be turned 
on at rst command received (use recommended battery-powered and / or solar panel).
• 000: “Energy saving” not active
• 001: “Energy saving” active
OUTPUT_2 functioning selection:
If=0 “boost” output for electric lock power supply art. 110; If=1 xed ashing output (for ashing lights with internal intermittent 
circuit); If=2 intermittent ashing output; If=3 Fixed open gate LED” (output always On when the gate is open, OFF at the end of 
a closure manoeuvre); If=4 Intermittent open gate LED” (slow intermittent output during opening and fast during closing, always 
ON with gate open, always OFF only at the end of a closing manoeuvre); If=5 Courtesy light” (output ON during every movement, 
OFF when the motor stops, after the delay set); If=6 24V output for electric lock in xed mode; If=7 24V output for electric lock in 
inverted mode; If=8 output for accessories power supply; If=9 24V commanded by ELOCK_IN input in impulse mode; If=10 24V 
output commanded by ELOCK_IN input in bistable mode; If>10 24V output commanded by ELOCK_IN input in timed mode (the 
value set indicates the switch-off delay in seconds).
Warning: If P062=8, output functioning is determined by the functioning envisioned in parameters P061 (Energy Saving) and 
P071 (Safety devices autotest).
• 000: “boost” output for electric lock power supply art. 110
• 001: “xed ashing output
• 002: “intermittent ashing output
• 003: “Fixed open gate LED
• 004: “Intermittent open gate LED
• 005: “Courtesy light (switching off delay set from P052)
• 006: “24V   xed electric lock output max 5W
• 007: “24V   inverted electric lock output max 5W
• 008: “24V   accessories power supply output max 5W
• 009: “24V   impulse mode output max 5W
• 010: “24V   bistable mode output max 5W
• >010: “24V   temporized output max 5W
(11sec………………255sec)