OPERATING PARAMETERS
Unused parameter
Unused parameter
Maintenance Operations-counter: if =  0  reset  the  counter and disables the intervention request , if> 0 indicates the  number 
of  operations  (x 500)  to be  made  before the  control panel  executes a 4  second additional  pre-ash  to indicate the  need of 
maintenance.
i.g.: If P065 = 050, operations number = 50x500 = 25000 operations
Warning: Before you set a new value of the counter-manoeuvres maintenance, the same must be reset by setting P065= 0 and 
only later P065 = “new value”.
• 000: “Request Maintenance disabled
• >000: “Number of operations (x 500) for required maintenance
(1...................................255)
OUTPUT_1 functioning selection:
If=1 xed ashing output (for ashing lights with internal intermittent circuit); If=2 intermittent ashing output; If=3 Fixed open 
gate LED” (output always On when the gate is open, OFF at the end of a closure manoeuvre); If=4 Intermittent open gate LED” 
(slow intermittent output during opening and fast during closing, always ON with gate open, always OFF only at the end of a closing 
manoeuvre); If=5 Courtesy light” (output ON during every movement, OFF when the motor stops, after the delay set); If=6 24V 
output for electric lock in xed mode; If=7 24V output for electric lock in inverted mode; If=8 output for accessories power supply; 
If=9 24V output commanded by AUX_IN input in impulse mode; If=10 24V output commanded by AUX_IN input in bistable mode; 
If>10 24V output commanded by AUX_IN input in timed mode (the value set indicates the switch-off delay in seconds).
Warning: If P066=8, output functioning is determined by the functioning envisioned in parameters P061 (Energy Saving) and 
P071 (Safety devices autotest).
• 001: “xed ashing output
• 002: “intermittent ashing output
• 003: “Fixed open gate LED
• 004: “Intermittent open gate LED
• 005: “Courtesy light (switching off delay set from P052)
• 006: “24V   xed electric lock output max 5W
• 007: “24V   inverted electric lock output max 5W
• 008: “24V   accessories power supply output max 5W
• 009: “24V   impulse mode output max 5W
• 010: “24V   bistable mode output max 5W
• >010: “24V   temporized output max 5W
(11sec………………255sec)
SAFETY 1
Operation of the SFT input: if = 0 safety edge always enabled, if = 1 safety edge enabled only while closing, if = 2 
safety edge enabled only while closing and before any movement, if = 3 safety edge enabled only when opening, if 
= 4 safety edge enabled only while opening and before any movement; as for the obstacle detection with internal 
anti-crushing sensor, also the activation of the inputs SFT1 and  SFT2 causes the complete or partial reversal as 
set by P055 (duration of inversion on obstacles while opening, and P056 (duration of reversal on obstacle while 
closing)
• 000: “safety edge always enabled
• 001: “safety edge enabled only while closing
• 002: “safety edge enabled only while closing and before any movement
• 003: “safety edge enabled only when opening
• 004: “safety edge enabled only while opening and before any movement
SAFETY 2
Unused parameter
Adjustment of acceleration durability
Warning: if soft start is activated, the acceleration is deactivated indipendently from P070 value.
• 000: “acceleration deactivated (it runs an acceleration of minimum durability, 
almost imperceptible)
• 00X: “adjusts the acceleration durability at 1,5 sec (X*6 ms)
(1...................................255)
Safeties self-test: if = 0 24V  output with autotest disabled; if = 1 24V  output for safeties with self-test (it turn the output off and 
check the contact opening before each maneuver).
Warning: In order to work in self-test mode, all devices must be connected to the congurable 24V output (7-8 for OUTPUT_1) (16-
17 for OUTPUT_2) with P062 and/or P066 = 8, and be wired and aligned before the motor stroke learning (P003).
• 000: “net power supply (safeties self-test disabled)
• 001: “safeties self-test enabled
Activation of SAS function (with NET_EXP only): SAS output is connected to an input STOP / SAS INPUT of a second control panel, 
causing the operation “trap man” (disabling the opening of the second door as long as the rst is not completely closed). 
If this parameter is enabled after a reset, it performs an automatic RESP during which the SAS output is not activated. If limit 
switches are present and they are crushed after a reset, the RESP is not executed. 
Warning: if both doors are manually unlocked and moved from the closed position creates the interlock condition. You will then 
need to manually close at least one of the two doors.
• 000: “SAS function” deactivated
• 001: “SAS function” activated